+ Stroke K A + Stroke M G J W 16 Minimum lead wire bending radius 10 Auto switch Q F 4 x N through H thread effective depth C 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A B A B 12 5 to 30 19.5 16 23 19.5 6 6 23 4 21.5 M3 x 0.5 26 1.5 5 3.5
Allowable load mass on guides/Allowable moment w 3 Table 4.
V V V Detection combinations A V V B V V C V V Two auto switches Two positions of q, w and e can be detected. Pattern Step 1) Fully close the fingers. Step 1) Position fingers for gripping a workpiece. Step 1) Fully open the fingers.
B [ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 W 5.5 0 0 2.5 W 7.5 2.0 2.0 0.5 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 A 16.5 15.0
A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.
D-M9WV D-M9AV D-A9 D-A9V A B C W A B C W 100 mm stroke or less 101 mm stroke or more 100 mm stroke or less 101 mm stroke or more 100 mm stroke or less 101 mm stroke or more 100 mm stroke or less 101 mm stroke or more 100 mm stroke or less 101 mm stroke or more 100 mm stroke or less 101 mm stroke or more Bore size 12 7.5 7.5 10 19.5 22 4.5 2 3.5 3.5 6 23.5 26 1 16 9 7.5 10.5 19.5 22.5 4.5
W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L. W L Mounting hole W Intermediate support mounting hole L L Distance between Load and Supports Mounting hole 140 130 25 120 CY3B CY3R 110 100 CY1S 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed.
25 M9BW 50 Compact Guide Cylinder Made to Order For details, refer to page 499.
8 e w !7 t !5 r o !8 e !6 w @0 !7 t !5 r o !8 e !6 w @0 !7 t !5 !0 u !2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !0 u !3 !2 i q !1 !4 y !9 Open condition Component Parts Note No.
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 16mm, Stroke: 100mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 16mm, Stroke: 75mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Magnet: Built-in Magnet, Series: J2RA, Bore Size: 16mm, Stroke: 150mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting
Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 16mm, Stroke: 150mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: J79, Lead