Applicable models: D-A93, A93V
Please contact SMC when the AC welding current exceeds 16000 A.
D-A90V/D-A93V/D-A96V Note) q In a case where the operation load is an inductive load. w In a case where the wiring load is greater than 5 m. e In a case where the load voltage is 100 VAC. Please use the auto switch with a contact protection box any of the above mentioned cases. (For details about the contact protection box, refer to page 17.)
This product should not be used as a stopper.
Use a watchmaker driver whose grip dia. is 5 to 6mm when tightening the auto switch mounting screw.
Double clevis type Lock location Port (A) (A) (A) (A) (A) (A) (A) (B) (D) (B) (D) (B) (B) (D) (D) (B) (B) (B) (D) (D) (D) CLS (C) (C) (C) (C) (C) (C) (C) Cushion valve 1.
For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring). 2. Even if a proper plier (tool for installing type C snap ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6) 10 <15> 10.5 36.5 16.5 17.5 7.5 16.5 17.5 42 12.5 13.5 11.5 (9) 12.5 13.5 40 [ ]: Values for 5 mm stroke with 32 < >: Values for 10
D-A90V, D-A93V, D-A96V Note) A contact protection box should be used in any of the following conditions to prevent the shortening of the working life of the switch.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.098 lb.
Series CJ2 is auto switch capable Spring extend or spring return, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 150mm, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.098 lb. 359.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths CJ2 ROUND BODY CYLINDER. CYLINDER. ACTUATOR. 10MM CJ2 DBL-ACT AUTO-SW. 0.50391 lb. EE.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.06 lb. 359.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.093 lb.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.107 lb. 359.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.06 lb.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, CYLINDER, ACTUATOR, CJ2 ROUND BODY CYLINDER, EE, 10MM CJ2 DBL-ACT AUTO-SW, 0.3704 lb
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 0.03000 lb