(Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: With
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: With
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 25mm, Stroke: 150mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Non-locking Style, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Mounting Bracket
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: With
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: With
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 25mm, Stroke: 200mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 25mm, Stroke: 150mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
D-J51: 5ms or less MHZ2 Lead Wire Length MHZJ2 How to specify lead wire length MHQ (Example) MHL2 L D-A73 MHR Lead wire length 0.5m 3m L 5m Z N MHK MHS None Applicable to only connector type switch D-C MHC2 Note 1) Lead wire length Z: 5m Applicable to Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73 (C) (H)/A80C MHT2 Solid state switch: Made to order (Except D-F9, F9lV, F7lWV) D-A53/A54, D-Z73
(g) Stroke (mm) Model 15 10 5 C(D)U6-S,T C(D)U10-S,T C(D)U16-S,T C(D)U20-S,T C(D)U25-S,T C(D)U32-S,T 28(38) 25(35) 22(27) 48(58) 40(50) 36(41) 71(101) 56(86) 50(75) 133(170) 106(143) 95(128) 235(294) 193(252) 176(230) 347(425) 286(364) 262(335) For the weight of auto switch, refer to page 68 to 72.
(C) (C) (C) (C) (C) (C) CA2 6 Cushion valve CA2Q Double acting, Single rod Low friction type NCM CBA1 Double acting, Single rod Cylinder with end lock 1.
Mounting bolt C D Mounting Bolt Size for NCQ8B056 to 250(Without Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCQ8B056-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B075-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B106-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B150-012 025 037 050 062 075 087 100 125 150
4 C-9 MYM50-15AK0502 GMY50 MC-16 P44 C-4 C-11.2 MYM63-15AK0503 GMY63 MC-20 P53 C-4 C-14 GMY20 GMY16 GMY25 GMY32 MYB20-15-A7164 MYB16-15-A7163 RCS-8 RCS-10 P16 P12 TMY-25 TMY-32 5.1 x 3 x 1.05 4 x 1.8 x 1.1 7.15 x 3.75 x 1.7 8.3 x 4.5 x 1.9 7 x 4 x 1.5 7 x 4 x 1.5 C-6 C-7 MYMK-20-stroke Side seal assembly Polyurethane MYMK-16-stroke MYMK-40-stroke MYMK-25-stroke MYMK-32-stroke Note) Two
d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) CKQ D-M9ANote 2) BMA3-040S (A set of a, b, c, e) BMA3-050S (A set of a, b, c, e) BMA3-063S (A set of a, b, c, e) Auto switch Switch bracket (Resin) Transparent (Nylon)Note 1) d e White (PBT) c Switch holder b Auto switch mounting screw a * Band (a) is mounted so that the projected part is on the internal side (contact side
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
-X 545 C(L)KU32 Series Auto Switch Mounting 2 Auto Switch Mounting Height Applicable cylinder: C(L)KU32-X2321 C(L)KU32-X2322 D-P3DWA 44.5 23.5 D-M9V D-M9WV 40 35 D-A7 40 22 546 Auto Switch Mounting C(L)KU32 Series Auto Switch Mounting Bracket Part No.