Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: C73C--Reed, DC Volt >5 <24, LED, Connector, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 3 pcs., Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 3 pcs., Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Stroke: 350mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7PW--Solid State, 2-color Indication, 3 Wire PNP, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
DATA OUT 1 2 3 SET 1 2 SET MONOSASHI-KUN AC100V OUT1 COM OUT2 COM COM OUT3 Series Guide Series CE1 Bore size (mm) Available stroke range Standard stroke (mm) Series CEP1 Standard stroke (mm) Bore size (mm) 12 equiv. 250 400 500 300 175 200 150 125 100 75 50 100 25 75 50 25 12 25 to 150 20 equiv. 20 25 to 300 32 25 to 400 40 25 to 600 50 25 to 600 63 25 to 600 CEU1 CEU5 Output transistor system
Caution Standard stroke (mm) Note) Bore size (mm) 20 25 32 40 50 63 80 100 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 Note) Manufacture of intermediate strokes in 1 mm increments is possible. (Spacers are not used.)
How to Order Standard L 40 150 CM2Y L H7BW S 40 150 CDM2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
Up to 700 25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
, 200 201 to 350 D25 32 40 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200, 250, 300 -X Intermediate stroke is available, too. 20Applicable Auto Switch/Refer to page 9-15-1 for further information on auto switches.
Up to 700 45 25 150 Up to 700 25 45 MK(2) 1500 32 150 Up to 1000 32 50 RS Q G 40 200 Up to 1000 40 60 Note 1) The cylinder performance may not as expected when stroke is shorter than recommended stroke even they are available.
Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) 12 Series CG1Y Mounting bracket dimensions are the same as those of the low friction, double acting, single rod type of Series CG1Q.
Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.
C J G5-S 100 CV 250 = 0.7 200 MVGQ 0.5 0.1 0.3 150 CC 100 50 RB 0 1,000 2,000 3,000 J Maximum speed Vmax (mm/s) : Cylinder load ratio Vmax: Maximum speed (Refer to page 10-6-5.) D-X 20Data 10-6-19
50 Bore) Screw & Nut Kit included with cylinder Switch # Switch # Actuator Mounting Auto Switch Mounting Hardware (brackets,bands, screws & nuts) is identical to our CDS1 Tie Rod Mounting BT-12 (125/140 Bore) BT-16 (160 Bore) BT-18 (180 Bore) BT-20 (200 Bore) our new part # C95D Tie Rod Mounting BT-03 (32/40 Bore) BT-05 (50/63 Bore) BT-06 (80/100 Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150