Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: -, Rated Voltage: -, Electrical Entry: -, Light/Surge Voltage Supprressor: -, Manual Override: -, Vacuum Pressure Sensor: -, Output:
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: B2 [Supply Valve (N.O.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge Voltage
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure
Body Size: -, Port Thread: -, Port Size: -, Option: -, Flow Direction, Pressure Unit: -
Body Size: 4000, Port Thread: F (G), Port Size: 04 (1/2), Option: None, Voltage: None - Manifold Override, Electrical Entry: None - Manifold Override, Surge Suppressor: None or Manual Override, Flow Direction, Pressure Unit: Flow Direction: Left to Right
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 2 (Rear Exhaust), Thread: F (G), Port Size: 04 (1/2), Option: None, Semi-standard: None
Body Size: 3, Set Pressure: 0 (Body Size 1, 2: 0.73 to 29 psi [0.005 to 0.2 MPa]; Body Size 3: 1.5 to 29 psi [0.01 to 0.2 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 04 (1/2), Option: None, Semi-standard: None
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: F (G), Port Size: 04 (1/2), Option: None, Semi-standard: None
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 1 (Front Exhaust), Thread: F (G), Port Size: 04 (1/2), Option: None, Semi-standard: None