A33 A34 A43 A34 A37 C 7 C 7 C12 C11 C12 -X 6 -X 6 Chart 3, 4, 5 Chart 3, 4 Chart 4, 5 Combination is available only when all the conditions are fulfilled among the nation chart above.
Symbol: C19 Symbol: C18 Symbol: C11 Angle adjustment at the rotation starting point and the end point are at 5. Rotating range is changed. Rotation angle is at 180 10. The rotation starting point is on the perpendicular line (up). Angle adjustment at the rotation starting point and the end point are at 5. Rotating range is changed. Rotation angle is at 180 10.
IDFC60/70/80/90 Series 11.4 Connect the power cable and signal cable 11-3 IDX-OM-U010 Chapter 11 Option T 11.5 Electric circuit IDFC60/70-23-T SYMBOL DESCRIPTION CM Refrigerating compressor OLR Overload relay FM Fan motor MC Magnetic contactor MC2 Magnetic contactor for remote switch PRS High pressure switch ILS Switch with lamp THR Thermal relay C01 Capacitor for refrigerating compressor C11
power cable and signal cable 12-3 IDX-OM-V020 Chapter 12 Option T 12.5 Electric circuit IDFA60/70-23-T 230VAC 1PH 50Hz SYMBOL DESCRIPTION CM Refrigerating compressor OLR Overload relay FM Fan motor MC Magnetic contactor MC2 Magnetic contactor for remote switch PRS High pressure switch PRS2 Pressure switch ILS Switch with lamp THR Thermal relay C01 Capacitor for refrigerating compressor C11
. * The load ratio is obtained by the following formula: ((Load mass x 9.8)/Theoretical output) x 100% VEX VEX Conditions System Solenoid valve Speed controller Silencer Tubing diameter x Length A VEX31 22-02 AS4000-02 AN20-02 10 x 1 m B 12 x 1 m C VEX33 42-03 04 AS420-03 AN30-03 12 x 1 m D AS420-04 AN40-04 SGP15A x 1 m 1723 3 Port 3 Position Valve Body Ported VEX3 Series How to Order Air
Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300 250 200 New New AV2000-A 150 100 50 0 0 1 2 3 4 5 6 Number of needle rotations Needle valve Smaller profile and less work hours due to integrated silencer Built-in silencer (Option) When the silencer is mounted afterward: Model Shortened dimensions [mm] Silencer part number (when mounted afterward) AV2000-mS-A 37 AN20
Maintenance
Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300 250 200 New New AV2000-A 150 100 50 0 0 1 2 3 4 5 6 Number of needle rotations Needle valve Smaller profile and less work hours due to integrated silencer Built-in silencer (Option) When the silencer is mounted afterward: Model Shortened dimensions [mm] Silencer part number (when mounted afterward) AV2000-mS-A 37 AN20
Note) If it is pressurized from the port indicated with the arrow, the shaft rotates in the clockwise direction. 90 +4 0 Symbol: C10 Symbol: C11 The rotation range is changed. The rotation range is changed.
Note) If it is pressurized from the port indicated with the arrow, the shaft rotates in the clockwise direction. 90 +4 0 Symbol: C10 Symbol: C11 The rotation range is changed. The rotation range is changed.
Applicable fitting size Noise reduction (dB) Effective area (mm2) (Cv factor) Series Model A L D d D VQC2000 10 AN20-C10 36.5 57.5 30 16.5 30 Elbow fitting assembly VVQ2000-F-L(C4/C6/C8/N3/N7/N9) It is used for piping that extends upward or downward from the manifold.
Applicable fitting size Noise reduction (dB) Effective area (mm2) (Cv factor) Series Model A L D d D VQ2000 10 AN20-C10 36.5 57.5 30 16.5 30 Elbow fitting assembly VVQ2000-F-L(C4/C6/C8/N3/N7/N9) It is used for piping that extends upward or downward from the manifold.
Symbol: C19 Symbol: C18 Symbol: C11 Angle adjustment at the rotation starting point and the end point are at 5. Rotating range is changed. Rotation angle is at 180 10. The rotation starting point is on the perpendicular line (down). Angle adjustment at the rotation starting point and the end point are at 5. Rotating range is changed. Rotation angle is at 180 10.
for Mounting Information) K Non-rotating Piston Rod (5 to 14) O P T I O N S A Special Rod Thread (See Page 22) B5 Oversized Rod (See Char t below) B6 High Temperature * C3 Por t and Cushion Location (see Page 23) C6 Stainless Steel Piston Rod (Std. on XTSS series) C8 Adjustable Stroke Extended Piston Rod * C9 Adjustable Stroke Return Piston Rod * C10 Dual Operation/Double Piston Rod * C11
for Mounting Information) K Non-rotating Piston Rod (5 to 14) O P T I O N S A Special Rod Thread (See Page 22) B5 Oversized Rod (See Char t below) B6 High Temperature * C3 Por t and Cushion Location (see Page 23) C6 Stainless Steel Piston Rod (Std. on XTSS series) C8 Adjustable Stroke Extended Piston Rod * C9 Adjustable Stroke Return Piston Rod * C10 Dual Operation/Double Piston Rod * C11
Load factor: ((Load weight x 9.8) /Theoretical force) x 100% Construction Conditions Base mounted Series CJ2 Series CM2 Series MB, CA2 Tube x Length Speed controller Silencer Tube x Length Speed controller Silencer T0604 x 1 m AS3002F-06 AN110-01 SQ1000 AN20-02 AS4002F-10 T0604 x 1 m AS3002F-06 T1075 x 1 m T1209 x 1 m SQ2000 Front matter 2 EX510 Gateway-type Serial Transmission System Plug-in
Load factor: ((Load mass x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3302F-06 12 x 1 m AS4002F-12 AN20-02 AS2302F-06 AN110-01 Series MB/CA2 Series CJ2 Series CM2 Series MB/CA2 Body ported Tubing diameter x Length Speed controller Silencer Base mounted Tubing diameter x Length Speed controller Silencer AN20-02 AN3301F-06 AS1302F-06 6 x 1 m AS3002F-06 10-SYJ7123
Note) If it is pressurized from the port indicated with the arrow, the shaft rotates in the clockwise direction. y 9 0 +4 0 Symbol: C10 Symbol: C11 Change of rotation range Change of rotation range of k e e g y n w a R o a t r a y ti Note) If it is pressurized from the port indicated with the arrow, the shaft rotates in the clockwise direction. n o 1 o n r 8 ti a a 0 n +4 0 ot g R e of k
Silencer Compact resin type Metal body type High noise reduction type Part Part number number AN20-02 AN30-03 AN40-04 AN500-06 AN600-10 AN202-02 AN302-03 AN402-04 ANA1-06 ANA1-10 Piping size 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 AMA20#-##C-#-#L# NC AMA20#-##D-#-#L# NO AMA30#-##C-#-#L# NC AMA30#-##D-#-#L# NO AMA40#-##C-#-#L# NC AMA40#-##D-#-#L# NO AMA60#-##C-#-#L# NC AMA60#-##D-#-#L# NO -147No.PF-OMA1007
Therefore, install a silencer (SMC Series AN20 or AN40) on the exhaust port (EXH port). The port sizes are Rc 1/8, Rc 1/4 and Rc 1/2. 12. Specifications on page 815 and 844 is in case of static environment. Pressure may fluctuate when air is consumed at the output side. ARX AMR ARM ARP IR IRV Design and Selection Caution VEX SRH 1.