Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 60, Actuation: Normally Open, Pressure Display Unit: Units Selection Function
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 40, Actuation: Normally Open, Pressure Display Unit: SI Units Only
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 40, Actuation: Normally Closed, Pressure Display Unit: SI Units Only
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 60, Actuation: Normally Open, Pressure Display Unit: SI Units Only
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 60, Actuation: Normally Closed, Pressure Display Unit: SI Units Only
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only)
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: F (G), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: F (G), Port Size: 10 (1), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 30, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Thread type (Including pilot port) VA Nil F N T Rc G NPT NPTF SA Port size (P, A, B port) VA 01 02 1 8 1 4 Option R1, R2 port are 1/8.
DO1 Speed reached SA When the servo motor speed reaches the following range, SA will turn on. Set speed ((Set speed 0.05) + 20) r/min When the preset speed is 20 r/min or less, SA always turns on.
SA SA/ /INP PD13 23 O ZSP ZSP ZSP ZSP ZSP ZSP PD14 24 O INP INP/SA SA SA/ /INP PD15 25 O TLC TLC TLC TLC/VLC VLC VLC/TLC PD16 26 (Note 3) (Note 3) 27 I TLA (Note 3) TLA/TC TC TC/TLA TLA TLA 28 LG LG LG LG LG LG 29 30 LG LG LG LG LG LG 31 32 33 O OP OP OP OP OP OP 34 LG LG LG LG LG LG 35 I NP NP/ /NP 36 I NG NG/ /NG 37 38 39 40 41 I CR CR/SP1 SP1 SP1/SP1 SP1 SP1/CR PD08 42 I EMG EMG EMG EMG