~ 1000 ULo (Rated lower limit for connection product [USEr]) Y S16 0x0 10 R/W (0) UHi (Rated upper limit for connection product [USEr]) Set the rated upper limit when "range added by the user" is selected. -1000 ~ 1000 Y S16 0x03E8 (1000) 11 R/W Set the accumulated minimum unit when the user's additional range is selected. 0: 0.1 1: 1 2: 10 3: 100 UAC (Accumulated minimum unit for connection
m (kg) 1000 a = 1000 to 3000 L2 500 Mer m 5 10 0 Transfer load m (kg) a 1000 Mey a = 1000 to 3000 500 m L3 5 10 0 Transfer load m (kg) Refer to page 304 for deflection data. 268 5 Phase Stepper Motor/Without Motor Brake Series LXS Dimensions/LXSH5BD Scale: 25% F G x I +0.030 0 depth 5 +0.030 0 depth 5 5H9 D-5.1 through Refer to Cross section C-C, bottom view.
(Assuming approximately 30% dispersion) There may be the case to change substantially depending on an ambient environment. 4 4 4.5 5 6 6.5 6.5 7 8 10 9 10 10 11 D8 10 9 10 10 11 5 5 5.5 6 7 7.5 7.5 8 11 11 13 13 14 14 14 17 35 40 40 45 45 45 45 50 16 18 -X 8 10 9 10 10 11 Individual -X 387 Series MGG Auto Switch Mounting Bracket: Part No.
Change "Safe func set2" from "1000" to "0". Select the tag "Drive". Change "Safe func set2" parameter from "1000" to "0". OFF : 0 ON : 1000 Select download Select the "Download" button. The modified data is transmitted to the driver.
CY3B15 CY3B50 1000 500 50 40 30 20 300 200 10 5 100 Usable range Usable range 20 30 40 50 1 0 1 2 3 4 5 6 10 0 1 2 3 4 5 6 Distance from cylinder shaft center Lo (cm) The Lo point from the cylinder shaft center is the moment working point between the cylinder and the load section. 7 8 9 10 11 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center Lo (cm) CY3B63 CY3B20 200 1000 100 500
Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s mm mm/s2 mm/s2 mm mm mm mm/s 0 1 Absolute 100 50.00 1000 1000 0 0 0 100 0 0 0.1 2 Relative 50 10.00 1000 1000 0 0 0 100 0 0 0.1 (E.g.) Flow chart Controller (1) Select/input Step No.1.
Straight type V Elbow type Fitting size One-touch fittings for regulator Straight V 2.5 3 6.5 Elbow W 6 6.5 6 Elbow X 11 11 11.5 Elbow Y 35.5 36 38.5 4, 5/32 6 1/4 8, 5/16 W X Y Note) The O-ring is attached.
10 D-B5/B64 8 9 10 10 11 11 11 10 D-B59W 13 14 14 14 17 16 18 13 D-H7/H7NF/H7W/H7BAL 4 4.5 5 6 6.5 6.5 7 4 D-H7C 7 9 10 9.5 10.5 10.5 11 8.5 D-A3/A44 9 9 10 10 11 11 11 10 D-G39/K39 8 9 9 9 10 10 11 9 4 D-G5/K59/G5W D-K59W/G5BAL/G5NTL Since this is a guideline including hysteresis, not meant to be guaranteed.
Facility water temp. 25 1500 Cooling capacity[W] 1500 25 Cooling capacity[W] 32 32 35 35 1000 1000 500 500 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T1 is selected.
11 11 11 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 20 20 20 2-2.6 (For mounting) (2.3) (2.3) 20 (2.3) 23 23 23 23 27 Refer to back page 11 for dimentions with connector cable. 28 Series SYJ5000 2 Position Double [ ]: AC G H Grommet (G), (H): SYJ5220-M5 Built-in one-touch fitting: SYJ5220G H C4, N3 C6, N7 G: Approx. 300 H: Approx. 600 (Lead wire length) 87.2 [91.6] 43
[Normal mode] Step data example Pushing Pushing Moving In Position Acceleration Trigger LV AREA 1 AREA 2 No Movement Speed Deceleration force speed force position [mm/s2] [mm/s2] . mode [mm/s] [mm] [] [mm] [mm] [] [mm/s] [] [mm] 0 1 ABS 100 100.00 1000 1000 50 40 10 100 0 0 5 2 ABS 50 50.00 1000 1000 0 0 0 100 0 0 0.1 (E.g.) Flow chart Controller Select/input Step No.1.
10 9 8 8 9 10 11 1 + 2 + 3 + 4 + 5 + + 5 + 4 + 3 + 2 + 1 6 6 12 13 14 15 15 14 13 12 10 10 6 + 7 + 8 + 9 + 10 + + 10 + 9 + 8 + 7 + 6 PWR PWR 11 11 COM COM 15 15 11 + 12 + 13 + 14 + 15 + + 15 + 14 + 13 + 12 + 11 5A 5A 0V +24V +24V 0V 2 x M4 Mounting hole Shown with cover removed. 60 1711 Series EX510 Parts Description i w t Output Unit No.
1000 0 0 0 100 0 0 0.1 2 INC 50 10.00 1000 1000 0 0 0 100 0 0 0.1 () 1No.1(IN0ON) / 2DRIVEON (2)(5)(10)(13) No.1 DRIVE (1) No.
Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s (mm) mm/s2 mm/s2 (mm) (mm) (mm) mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0, 1 (E.g.) Flow chart Controller (1) Select Step No.1.
30 27 60 22 44 16 32 33 15 51 8 M8 x 1.25 M14 x 1.5 6 14 11 1/4 27 102 164 40 Up to 1000 35 32 70 27 52 20 40 35 17 58 11 M8 x 1.25 M18 x 1.5 7 18 11 3/8 30 108 177 50 Up to 1000 35 32 85 27 64 20 40 35 17 58 11 M10 x 1.25 M18 x 1.5 7 18 14 3/8 31 116 188 63 Axial Foot Style (L) / CA2L, CA2L 10112122Relief port M5 x 0.8 2-cushion valve H GA AL A K 7 6 GB 4-J Width across flats B1 2-RcP H1
12 10,11 10,11,12 08,09 1000 10 15 8 500 06,07 10 6 500 4 5 2 0 0 5 10 0 5 10 0 Number of needle rotations Number of needle rotations 15-9-101 11 Construction ASD230F ASD330F/430F ASD530F/630F ASD530F-02 !
Maximum stations are 18. 18 6 19 7 20 8 21 9 22 10 23 11 24 1.
(Using Step No.2) [Normal mode] Step data example Pushing Trigger Pushing Moving Move Accele Decele Speed Position Area1 Area2 In position No. ration ration force L V speed mm/s force ment MOD mm/s mm mm mm mm mm/s2 mm/s2 % % % 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 Flow chart (example) Controller (1) Select/ input No.1 (Turn
Move mm/s2 mm/s2 mm/s mm mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 28 - Details of step data Setting name Range Description No. 0 to 63 Number of the step data. The setting to specify the coordinate system for the target position.
Move mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 Caution Writing of the step data should be performed while the electric actuator is stopped 59 - Details of step data Setting name Range Description No. 0 to 63 Number of the step data.