Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: BE4 (B+E4), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: BM (B+M), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 03 (3/8), Options: E4 (Output: PNP; Electrical Entry: Wiring Top Entry), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 03 (3/8), Options: M (Round Type Pressure Gauge, w/Color Zone), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: E2 (Output: NPN; Electrical Entry: Wiring Top Entry), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 03 (3/8), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: H (w/Set Nut, for Panel Mount), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 03 (3/8), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 03 (3/8), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 02 (1/4), Options: BE (B+E), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 03 (3/8), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 03 (3/8), Options: BG (B+G), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 25, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: BG (B+G), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa