High vacuum angle valve series XL provides excellent thermal conductivity results in a uniform temperature for the entire valve body and a marked decrease in the condensation of gases inside the valve. The valve does not contain heavy metals such as Ni (nickel) or Cr (chrome) and a low sputtering yield also helps to minimize heavy metal contamination of semiconductor wafers.

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Valve specifications Model XLG-16-2 XLG-25-2 XLG-40-2 XLG-50-2 XLG-63-2 XLG-80-2 Flange (valve) size 16 25 40 50 63 80 Actuating type Double acting (Dual operation), Pressurize to open/close Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (5 to 150 for high temperature type) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-5 Conductance l/s Note 1) 5 14 45 80 160 200 Internal

Please contact SMC for details. 14 XLG Series Specifications Model XLG-16-2 XLG-25-2 XLG-40-2 XLG-50-2 XLG-63-2 XLG-80-2 Valve type Double acting (Dual operation), Pressurize to open/close Fluid Inert gas under vacuum Operating temperature [C] XLG 5 to 60 (High-temperature type: 5 to 150) Operating pressure [Pa(abs)] Atmospheric pressure to 1 x 105 Conductance [L/s]*1 5 14 45 80 160 200 Leakage

1 CE-compliant Q CE-compliant Nil 437 XLG/XLGV Series Specifications Model XLG(V)-16 XLG(V)-25 XLG(V)-40 XLG-50 XLG-63 XLG-80 XLG-100 XLG-160 Valve type Double acting (Dual operation), Pressurize to open/close Fluid Inert gas under vacuum XLG 5 to 60 (High temperature type: 5 to 150) Operating temperature (C) XLGV 5 to 50 Operating pressure (Pa) (abs) Atmospheric pressure to 1 x 10-5 Conductance

J 26 28 36 38 45 56 Model XLG-16 XLG-25 XLG-40 XLG-50 XLG-63 XLG-80 Model 12 11 11 11 11 39 63 68 69 96 39 63 68 69 96 XLG-50 XLG-63 88 95 110 Note 1) Dimension E applies when heater option is included.