High vacuum angle valve series XL provides excellent thermal conductivity results in a uniform temperature for the entire valve body and a marked decrease in the condensation of gases inside the valve. The valve does not contain heavy metals such as Ni (nickel) or Cr (chrome) and a low sputtering yield also helps to minimize heavy metal contamination of semiconductor wafers.
It was confirmed that XLD-25, XLD-40 XLD-50, XLD-63 and XLD-80 satisfied the product specification up to 2 million cycles, XLD-100 and XLD-160 did up to 1 million cycles. Test piece posture: lateral : The test was performed with FKM, the standard sealing material.
Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF(NW), Port Direction: K (w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface), Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF(NW), Port Direction: w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface, Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: -, Body Surface Treatment: -, Seal