Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. VXR2 prevents damage of piping, equipment and generation of vibration through an integrated check valve and low valve closing speed. Variations include energized open (N.C) and energized closed (N.O) valves, bronze body material and NBR, FKM seal materials. Flow rate ranges from Cv of 6.5 to
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
H=0.1 m Fs=20 N If MSUA7 is selected under those conditions, thrust load of 20N will be within the allowable value of 60N, Fig.3 but moment will be 20N X 0.1m=2Nm, and it exceeds the allowable moment of 0.9Nm, so that it can not be used.
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to Best Pneumatics No. 5. Lubrication Caution 1. The non-lube type air gripper is lubricated at the factory, and can be used without any further lubrication.
Handling of pilot valves Be sure that forces exceeding 20N are not applied to the pilot valves due to lead wire deflection and external forces, as this may cause damage. Piping Caution 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 2.
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 240VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector)