The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding
Stations: 4 Stations, Port Size: 03 (3/8), Thread: Rc, S Kit: SQA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Polarity: Positive Common, Option: S (Direct Exhaust)
Stations: 4 Stations, Port Size: 3/8, Thread: Rc, S Kit: DeviceNetâ„¢ - 32 Outputs - Connector M12, SI Unit Polarity: Positive Common, Option: Direct Exhaust
For VQC4000 base mount, plug-in valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Replaceable one-touch fittings, 1 to 8 stations available as standard, MFLD, PLUG-IN,, VALVE, VV5QC41 MANIFOLD VQC 5-PORT, QP, VV5QC41 BASE MNT 3/8, 22.26668 lb
Electrical Wiring Specifications Lead wire specifications Lead wire length VV5QC41 08 C12 LD 0 Lead wire 0.3 mm2 x 25 cores As the standard electrical wiring specification used is for 12 stations or less, double wiring (connected to SOL. A and SOL. B) is used for the internal wiring of each station regardless of valve and option types.