SMC Corporation of America
Elite Part Number Search
Search Results "VQD1151V-6L"
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, .08800 lb

VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time.

  • Fluid: Air/inert gas
  • Operating pressure range: 0MPa
Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

4 Port Solenoid Valve Direct Operated Poppet Type Series VQD1000 How to Order Valves 5 1 5 L 1 VQD1 Type of actuation Made to Order Fluid-contact part: Oil-free X16 (A) 4 (B) 2 Single type Port size 1 M5 Nil M5 M5 thread Without sub-plate (Manifold) M5 thread Body ported 1 (P) 3 (R) Base mounted (A) 4 (B) 2 Latching type Electrical entry 2 L: Plug lead type L plug connector, With lead wire

Series VQD1000 4 Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times Compact and lightweight (34 g) with large flow capacity ON: 4 ms, OFF: 2 ms, Dispersion accuracy 1 ms (With light/surge voltage suppressor at a supply pressure of 0.5 MPa) (Use clean and dry air.) Body width of 10 mm, C: 0.22 dm3/(sbar) 2 W C: 0.27 dm3/(sbar) 3.2

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot Air Supply: Internal

Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: V (Vacuum), Voltage: 6 (12 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire; with Light/Surge Voltage Suppressor), Port Size: M5

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC12V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot

Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: V (Vacuum), Voltage: 6 (12 VDC), Electrical Entry: LO (L Plug Connector, w/o Connector; with Light/Surge Voltage Suppressor)

VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum

VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper, 4 PORT VALVE, 4/5 PORT SOLENOID VALVE, 34 lb

VS7 (Rated voltage: 24V DC) How to Use the Valve for Vacuum Applications (When used as a 3 port valve) Applied voltage 24V Caution 0V Application example of VQD1151 V/W (Symbols used are typical.) 4W Power saver 2W Vacuum valve 0W 10ms 3(R) 4(A) Vacuum pad How to Mount Valve 1(P) 2(B) Air for vacuum release atmosphere or air pressure Caution Use a VQD1151V

Body: 5 (Base Mounted), Valve Option: V (Vacuum), Voltage: 6 (12 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire)

Since this is equivalent to 45% of the discharge rate for fresh water, 2.7l/min 0.45 = 6l/min, indicating that a discharge rate of 6l/min is required for fresh water. 3.

Note 3) When using D-M9mA(V)L, order stainless mounting screw kit BBA1 instead of the iron auto switch mounting brackets (BMB5-032, BA7-mmm, BS5-125) in the table above, and use the M4 x 6L stainless set screws included.

Since this is equivalent to 45% of the discharge rate for fresh water, 2.7l/min 0.45 = 6l/min, indicating that a discharge rate of 6l/min is required for fresh water. 3.

Since this is equivalent to 45% of the discharge rate for fresh water, 2.7l/min 0.45 = 6l/min, indicating that a discharge rate of 6l/min is required for fresh water. 3.

Set of nos. above @2, @3, @4 8-29-6 7 Dual Rod Cylinder: Basic Type Series CXS Dimensions: 6 ZZ (58.5 + ST) ST SS (45 + ST) 16 8 5.5 Z (10 + 1/2 ST) 2-3.4 through 2-6.5 counterbore depth 3.3 M3 x 0.5 x 5l (Hexagon socket head set screw) 14 1 2.75 13 3 3 OUT 1 MX 5.6 3.2 MTS 0.2 28 0.2 22.7 (16) 37 35 16 28 MY 6.3 5 CY M2.5 x 0.45 x 6l 6 (Hexagon socket headcap screw) M3 x 0.5 x 12.5l, M3

Number of High Voltage Cable Holder 4H / 4L 160 to 220 160 to 460 4H / 4L 160 to 460 160 to 820 4H / 4L 160 to 1600 160 to 2500 6H / 6L 160 to 580 160 to 1120 6H / 6L 160 to 1120 160 to 2320 6H / 6L 160 to 2500 160 to 2500 8H / 8L 160 to 820 160 to 1900 8H / 8L 160 to 1900 160 to 2500 8H / 8L 160 to 2500 160 to 2500 Symbol IZT40 IZT41 IZT42 AH / AL 160 to 1600 160 to 2500 AH / AL 160 to 2500