The AC-D series of modular F.R.L. brings a modern appearance to SMC's line of air preparation equipment while maintaining the high performance of our other series. The maximum set pressure of the AC-D is 125 psi allowing use in a broad range of applications. Most of the features of the AC-A and -B have been incorporated into the AC-D - transparent bowl guards for full visibility; embedded
Y200-A Y300-A Y400-A Y500-A Y600-A Applicable air preparation equipment AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A VHS20 VHS30 VHS40 VHS40-06 VHS50 Note) VHS50 can be connected to AC55 and AC60. Spacer IN OUT Spacer with bracket 1
F 28 30 36 44 54 E 33 42 44 50 61 D 45 55 58 65 76 C 20 29 39 42 53 B 59 78 107 110 134 AA 34 46 63 67 78 A 40 53 70 75 90 H 45 55 63 69 81 G 22 21 26 Model VHS20 VHS30 VHS40 VHS40-06 VHS50 Caution on Mounting 1.
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
22.8 0.49 6.3 P2 (Port size) EXH Model P1 P2 A B C D Applicable size VHS20-D 1/8, 1/4 1/8 48.5 23 40 37 AC20-D VHS30-D 1/4, 3/8 1/4 55 32 53 49 AC30-D VHS40-D 1/4, 3/8, 1/2 3/8 69.7 41.3 70 63 AC40-D VHS40-06-D 3/4 1/2 71.7 43.3 75 63 AC40-06-D VHS50-D 3/4, 1 1/2 86.5 44.5 90 80 AC50-D/AC60-D Model E F G H Applicable size VHS20-D 28 42 17.5 40 AC20-D VHS30-D 38 53 20 53 AC30-D VHS40-D 52