SMC Corporation of America
Elite Part Number Search
Search Results "RDQB25-25M-A93V"
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, AIR CUSHION, ACTUATOR, RQ COMPACT CYLINDER, IE, 25MM RQ DBL-ACT AUTO-SW, .76059 lb

The RQ series air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end.

  • Unique air
Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

A96 A96V 5 V IC circuit Yes A72 A72H 200 V 100 V 12 V Grommet A93 A90 A93V A90V No IC circuit 5 V,12 V 12 V Relay, PLC 100 V or less 2-wire A73C A80C A79W 24 V Yes No Connector IC circuit 5 V,12 V 24 V or less Yes Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with a "" are produced upon receipt of order.

A96V A96 IC circuit 5 V Yes A72 A72H 12 V 200 V 100 V Grommet A93V A90V A93 A90 IC circuit 5 V,12 V 12 V 100 V or less No Relay, PLC 2-wire A73C A80C A79W 24 V Yes No Connector IC circuit 5 V,12 V 24 V or less Grommet Yes Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ

Cylinder model C D Mounting bolt part no. *1RSQB12-10m 5 45 CQ-M3X45L RSQB16-10m 7.5 55 CQ-M3X55L -15m 60 X60L RSQB20-10m 7 Example) CQ-M3X55L 2 pcs. 55 CQ-M5X55L -15m 60 X60L -20m 65 X65L RSQB32-10m 9 Mounting bolt 60 CQ-M5X60L -15m 65 X65L -20m 70 X70L RSQB40-20m 9.5 C D 75 CQ-M5X75L -25m 80 CQ-M5X80L -30m 85 X85L RSQB50-20m 9 75 CQ-M6X75L -25m 80 X80L -30m 85 X85L *1 Be sure to use the

Applicable model: D-A93, A93V, C73, C73C, B53, B54 2) When using a 2-color indication type auto switch (D-B59W), the auto switch will constantly remain ON if the connections are reversed.

SERIES MXP Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Type Special Function Electrical Indication Wiring Load Voltage Auto Switch Part No Lead Wire Applicable Entry Light (Output) DC AC Electrical Entry Direction Length (m) Load Perpendicular In-Line 0.5 (Nil) 3 (L) A90V A90 Without 2 Wire 24V 5V, 12V 100V or less IC Circuit Relay PLC A93V

Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 25mm, Body Option: M (Rod End Male Thread)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket

Find the pilot air pressure and pilot air consumption for a discharge rate of 6l/min and a total lifting range of 25m. [The transfer fluid is fresh water (viscosity 1mPaS, specific gravity 1.0).] If the discharge pressure is required instead of the total lifting height, a total lift of 10m corresponds to discharge pressure of 0.1MPa. Caution 1.

Find the pilot air pressure and pilot air consumption for a discharge rate of 6l/min and a total lifting range of 25m. [The transfer fluid is fresh water (viscosity 1mPaS, specific gravity 1.0).] If the discharge pressure is required instead of the total lifting height, a total lift of 10m corresponds to discharge pressure of 0.1MPa. Caution 1.

Find the pilot air pressure and pilot air consumption for a discharge rate of 6l/min and a total lifting range of 25m. [The transfer fluid is fresh water (viscosity 1mPaS, specific gravity 1.0).] If the discharge pressure is required instead of the total lifting height, a total lift of 10m corresponds to discharge pressure of 0.1MPa. Caution 1.

Dimensions [mm] Model L1 L2 A B C D E F G J K 138 LEPS10m-25m 152.5 20 22 30 29 20 29 39 88.2 61.8 LEPS10m-50m 163 177.5 24 43 34 50 24 50 60 113.2 LEPS10Lm-25m 124 138.5 20 22 30 29 20 29 39 88.2 47.8 LEPS10Lm-50m 149 163.5 24 43 34 50 24 50 60 113.2 19 Series LEPY/LEPS Specific Product Precautions 1 Be sure to read before handling.

25M 63.5 N/A 43.0 2r0 Pl\41201\1 * PM225M PRO110M --+ PR0225M Alld mens ons in millmeterc, ACB AcD URETHANE STRIKER CAP (UC) QE, Cololoq 1{0. Port l{unber $odel (lef) A t, "ilf' u(E609 (98609079 PMft Alt 20 / 1 25M, 220 / 22yt r0.030.5 3 u(2940 (92940079 PMI5OOM 24.5 44.5 i 4 u(30t0 cs30l00t9Pti?

Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: M (1m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)