PF3W is a digital flow sensor that constantly monitors water or coolant flow. The -U variation features PVC piping for additional compatibility with deionized water and liquid chemicals. This is the remote version of PF3W7-U, without a display. One analog output is available. Options include a mounting bracket and M8 lead wire. This version does not offer a flow adjustment valve or temperature
Note) G, F, J: Made to Order Reference: 1 [L/min] 0.2642 [gal/min] 1 [gal/min] 3.785 [L/min] oF = 9/5oC + 32 Note 2) Note 2) Note 2) Note 2) Options/Part No. Lead wire Nil N When optional parts are required separately, use the following part numbers to place an order.
1 V 1.8 V 5 V Current output 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C Voltage output 1 V 1.48 V 5 V Current output 4 mA 5.92 mA 20 mA Rated flow [L/min] Sensor model Minimum Maximum PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0010-J Dimensions PF3W504
Similar items in stock.
PF3W520S [] [] P: P: PF3W540S [] P: -39No.PF-OMN0009CN-F () (PF3W504/520/540) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C
.: 38mm), Output Specification: 2 (OUT1: Analog 4 to 20mA)