PF3W is a digital flow sensor that constantly monitors water or coolant flow. PF3W refreshes the design and operating performance of the legacy PF2W model. This is the remote version of PF3W7, with a display. One or two analog outputs are available, depending on whether the optional temperature sensor is selected. Additional options include a mounting bracket, flow adjustment valve and
3-color display Digital Flow Switch for Water Series PF3W RoHS How to Order Remote sensor unit Output specification/Temperature sensor Remote sensor unit/Unit printed on label Symbol Temperature oC Symbol OUT1 Flow rate OUT2 Temperature Temperature sensor 1 2 1T Instantaneous flow rate L/min L/min (gal/min) For how to order of remote monitor unit, refer to page 18.
To use in combination with remote monitor (PF3W3 series), Note) G: Made to Order select analog output of 1 to 5 V of flow rate (output symbol -1 or -1T). Reference: 1 [L/min] 0.2642 [gal/min] 1 [gal/min] 3.785 [L/min] oF = 9/5oC + 32 Note) Analog output of 4 to 20 mA with temperature sensor is made to order. (Refer to page 10.)
(Metal attachment) PF3W521 (Metal attachment) -33No.PF-OMN0010-J PF3W511 (Vinyl chloride piping) PF3W521 (Vinyl chloride piping) -34No.PF-OMN0010-J Operating pressure and proof pressure PF3W504/520/540 PF3W504S/520S/540S PF3W511 (Metal attachment) PF3W521 (Metal attachment) PF3W511/521 (Vinyl chloride piping) -35No.PF-OMN0010-J Straight inlet pipe length and accuracy (reference value) Metal