Series PF3A digital flow sensor provides continuous quantitative values as well as switched digital outputs when set flow levels are measured.  When paired with an IO-Link master, measured values, settings, and device information can be accessed at an HMI screen or fieldbus networked monitoring device.  32-bit of process data include 16 bits for the measured value, 2 output bits for set points

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

(reed or solid state input) for 30 ms or longer -22No.PF-OMX0002-B Used as IO-Link device PF3A7##H-##-L#-## PF3A7##H-##-L3/L4#-## : Numbers in the figures show the connector pin layout. -23No.PF-OMX0002-B Example of wiring for accumulated pulse output NPN output type PF3A7##H-##-L/L3/L4#-## PNP output type PF3A7##H-##-L/L3/L4#-## -24No.PF-OMX0002-B Outline of Settings [Measurement mode] Power

(reed or solid state input) for 30 ms or longer -24No.PF-OMX0007-A Used as IO-Link device PF3A7##H-L#-##-# PF3A7##H-L3/L4#-##-# : Numbers in the figures show the connector pin layout. -25No.PF-OMX0007-A Example of wiring for accumulated pulse output NPN output type PF3A7##H-CS/DS/L/L3/L4#-##-# PNP output type PF3A7##H-ES/FS/L/L3/L4#-##-# -26No.PF-OMX0007-A Change the Function Settings [Function

[F14] Zero cut-off setting completed 46 No.PF-OMU0002-D Settable flow range when [L] is selected by the units selection function Displayable flow range Zero cut-off Zero cut-off set value range PF3A703H PF3A706H PF3A712H 0.0 0%F.S. 0 to 3150 L/min 0 to 6300 L/min 0 to 12600 L/min 30 to 3150 L/min 60 to 6300 L/min 120 to 12600 L/min 1.0 0 to 1%F.S.

(Hysteresis mode, error output, switch output off) (Window comparator mode) -48No.PF-OMU0007-D [F14] Display with zero cut-off setting When the flow is close to 0 L/min., the product rounds the value down and zero will be displayed. This is adjustable within the range of 10% F.S. of the flow range. Press the or button in function selection mode to display [F14].

[F 5] [ FnC] Select FUNC (switching Analogue output 2/ External input) [ oUt] Analogue output PF3A706H Equivalent to M5 3 Nm10% 8 PF3A712H 9 Equivalent to M6 5.2 Nm10% : Arbitrary display mode can be added to the sub display by setting the [F10] sub display.

(For accumulated increment) [H_1 ] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.

No display 123,450 L (only lower digits are displayed). 123,456,780 L 9,999,999,999 L (maximum accumulated flow value exceeded) -58No.PF-OMZ0002-A [F14] Zero-cut setting A function to force the display to zero to remove flickering at the lower measurement range. Press the UP or DOWN button in function selection mode to display [F14]. Press the SET button.

No display 123,450 L (only lower digits are displayed). 123,456,780 L 9,999,999,999 L (maximum accumulated flow value exceeded) -54No.PF-OMY0002 [F14] Zero-cut setting A function to force the display to zero to remove flickering at the lower measurement range. Press the UP or DOWN button in function selection mode to display [F14]. Press the SET button.

#-### (NPN) PF2M7##-#-L3/L4#-### (PNP) L3: NPN + Analogue voltage output type L3: PNP + Analogue voltage output type L4: NPN + Analogue current output type L4: PNP + Analogue current output type Maximum applied voltage: 28 V Maximum load current: 80 mA Internal voltage drop: 1.5 V or less Maximum load current: 80 mA Internal voltage drop: 1.5 V or less L3: Analogue output: 1 to 5 V, 0 to

Wide range of flow measurement with one product 6000 10 12000 Applicable flow range [L/min] Port size 30 60 120 500 1000 3000 30 3000 3000 L type PF3A703H 1 60 6000 6000 L type PF3A706H 1 1/2 120 12000 12000 L type PF3A712H 2 Pressure loss: 75% reduction*1 Improved drainage and resistance to foreign matter (20 kPa / 5 kPa) *1 Compared with the current model (PF2A7H/Large flow type).

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None]

Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: -, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -