Series PF3A digital flow sensor provides continuous quantitative values as well as switched digital outputs when set flow levels are measured. When paired with an IO-Link master, measured values, settings, and device information can be accessed at an HMI screen or fieldbus networked monitoring device. 32-bit of process data include 16 bits for the measured value, 2 output bits for set points
Direct parameters page 1 DPP1 address Access Parameter name Initial value (dec) Content 0x07 R Vendor ID 0x0083(131) "SMC Corporation" 0x08 PF3A703H-xx-Lx-xxx PF3A703H-xx-L3x-xxx PF3A703H-xx-L4x-xxx PF3A706H-xx-Lx-xxx PF3A706H-xx-L3x-xxx PF3A706H-xx-L4x-xxx PF3A712H-xx-Lx-xxx PF3A712H-xx-L3x-xxx PF3A712H-xx-L4x-xxx 0X0190(400) 0X0191(401) 0X0192(402) 0X0193(403) 0X0194(404) 0X0195(405) 0X0196
Select zero cut-off setting Press the or button to select the value of Zero cut-off. : The display above is an example of when [L] is selected for the PF3A703H(3000 L/min type) with the unit switching function. : If the flow rate does not reach the above value, the display will be zero. Example: PF3A703H (3000 L/min type) Press the S button to set. Return to function selection mode.
Wide range of flow measurement with one product 6000 10 12000 Applicable flow range [L/min] Port size 30 60 120 500 1000 3000 30 3000 3000 L type PF3A703H 1 60 6000 6000 L type PF3A706H 1 1/2 120 12000 12000 L type PF3A712H 2 Pressure loss: 75% reduction*1 Improved drainage and resistance to foreign matter (20 kPa / 5 kPa) *1 Compared with the current model (PF2A7H/Large flow type).
Item PF3A703H PF3A706H PF3A712H The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.
Before Use Digital Flow Switch PF3A703H/PF3A706H/PF3A712H-L Use the correct tightening torque for piping. (Refer to the table below for the required torque values.) If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the fittings may become loose. Avoid any sealing tape getting inside the fluid passage.
Flow switch flow setting and functions PF3A703H/PF3A706H/PF3A712H IO-Link function PF3A703H/PF3A706H/PF3A712H-L Function selection mode In this mode, each function setting can be changed separately. In measurement mode, press the S button for 3 seconds or longer to display [F 0]. Press the or button to select the function to be changed.
. -24No.PF-OMU0007-D Flow specification when [Ft] is selected by the units selection function Model PFG3#0 Model PFMB7201 PFMB7501 PFMB7102 PFMC7102 PFMB7202 PFMC7202 PF3A703H PF3A706H PF3A712H SMC Flow Applicable Switch PFMC7501 Rated flow range 0.08 to 7.06 cfm 0.2 to 17.7 cfm 0.4 to 35.3 cfm 0.8 to 70.6 cfm 1.1 to 105.9 cfm 2.2 to 211.9 cfm 4.5 to 423.8 cfm Instantaneous flow -0.36 to
1 270 (15) NAN300-N03 84 25 22 NAN700-N12 114 440 (24) NAN400-N04 92 30 27 NAN800-N14 112 590 (33) NAN500-N06 107 46 36 NAN900-N20 2 960 (53) NAN600-N10 132 50 41 Note: When ordering PT Ports, remove (N) from Model Number Eg: AN200-02 NAN700-N12 200 74 55 NAN800-N14 233 74 60 NAN900-N20 263 86 70 Courtesy of Steven Engineering, Inc. !
1 270 (15) NAN300-N03 84 25 22 NAN700-N12 114 440 (24) NAN400-N04 92 30 27 NAN800-N14 112 590 (33) NAN500-N06 107 46 36 NAN900-N20 2 960 (53) NAN600-N10 132 50 41 Note: When ordering PT Ports, remove (N) from Model Number Eg: AN200-02 NAN700-N12 200 74 55 NAN800-N14 233 74 60 NAN900-N20 263 86 70 Courtesy of Steven Engineering, Inc. !
Auto Drain Float Type Model NAD600-N10 Minimum operating pressure 45psi. Maximum operating pressure 145psi. 1 NPT top entry. (N10), 3/4 NPT (N06) Model NAD402-N04 (N04 = 1/2 NPT) Minimum operating pressure 22psi. Maximum operating pressure 145psi.
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)