Series PF3A digital flow sensor provides continuous quantitative values as well as switched digital outputs when set flow levels are measured. When paired with an IO-Link master, measured values, settings, and device information can be accessed at an HMI screen or fieldbus networked monitoring device. 32-bit of process data include 16 bits for the measured value, 2 output bits for set points
to 6000 L/min 120 to 12000 L/min Instantaneous flow 30 to 3150 L/min 60 to 6300 L/min 120 to 12600 L/min Set point range Accumulated flow 0 to 999,999,999,990 L 0 to 999,999,999,900 L Flow specifications Instantaneous flow 2 L/min 5 L/min 10 L/min Minimum resolution Accumulated flow 10 L 100 L Accumulated volume per pulse (Pulse width = 50 msec.)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: Rc, Port Size: 10 (1), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]
Rated Flow Range: 30 to 3000 l/min, Thread Type: Rc, Port Size: 1, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -