SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

PF2W is a digital flow sensor for water or coolant.  This is a legacy sensor, refreshed in 2009 as PF3W.  This is the remote version of PF2W7, with a display.  The mounting bracket is integrated into the body, while the M12 lead wire is optional.  PF2W5 can be paired with a PF2W200 or PF2W300 remote monitor to display instantaneous or accumulated flow values.  An optional analog output is also

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 23 Digital Flow Switch Series PF2W For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples to are the terminal numbers.

D 10 100 Analogue output A B C Voltage output 1 V 1.5 V (1.4V) 5 V Current output 4 mA 6 mA (5.6 mA) 20 mA The value in ( ) is when PF2W511 is used.

Flow Range: 11 (10~100 l/min), Thread: N (NPT Thread), Port Size: 10 (1"), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))

Flow Range: 11 (10~100 l/min), Thread: N (NPT Thread), Port Size: 10 (1"), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (1~5V)

Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (4~20mA)

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 19 Series PF2W For Water Digital Flow Switch to are terminal numbers.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 16 100 40 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 16 100 40 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to

Port size Nil N Lead wire with M12 connector (3 m) Without lead wire Port size Applicable model Flow rate (L/min) Symbol 100 4 16 40 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Output specifications Symbol Nil 1 2 Specification Series PF2W300 Series PF2W200/300 Series PF2W300 Applicable monitor unit (monitor) model Output for monitor unit Output

PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 23 Digital Flow Switch Series PF2W For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples to are the terminal numbers.

PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 19 Series PF2W For Water Digital Flow Switch Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples OUT2 NC Sensor 8 Load 41.8 4 4.3 40.3 OUT1 40 Black Main circuit Main circuit 7 3 Load Brown 6 2 +