Grippers with angular finger opening from 30° to -10° make the MHC2 suitable for workpieces of odd shapes and where space is too tight to accommodate a parallel type gripper.
Model Bore size (mm) Gripping moment (Nm) (Effective value) (1) Opening/closing angle (Both sides) Weight (2) (g) Action Model MHC2-10D MHC2-16D MHC2-20D MHC2-25D 39 91 180 311 0.10 0.39 0.70 1.36 10 16 20 25 30 to 10 Double acting MHC2-10S MHC2-16S MHC2-20S MHC2-25S 0.070 0.31 0.54 1.08 39 92 183 316 10 16 20 25 MHC2-16S 30 to 10 Single acting Note 1) At the pressure of 0.5 MPa.
Model Action Model Bore size (mm) Gripping moment (Nm) (Effective value) (1) Opening/closing angle (Both sides) Mass (2) (g) MHC2-10D MHC2-16D MHC2-20D MHC2-25D 39 0.10 10 91 0.39 16 Double acting 180 0.70 20 MHC2-16S 311 1.36 25 MHC2-10S MHC2-16S MHC2-20S MHC2-25S 0.070 39 10 MHC2-10D 0.31 92 16 Single acting 0.54 183 20 JIS Symbol 1.08 316 25 Double acting Note 1) At the pressure of 0.5
MH*-OMG0048 PRODUCT NAME Angular Type Air Gripper MODEL / Series / Product Number MHC2-6* MHCA2-6* MHCM2-7S Contents Safety Instructions 1. Specifications 2. Operating method 2-1. Precautions on design 2-2. Selection 2-3. Mounting 2-4. Air source 2-5. Piping 2-6. Environment 2-7. Lubrication 3. Maintenance 3-1. Notes 3-2. Exploded view 1 MHC2-6* 3-3. Exploded view 2 MHCA2-6* 3-4.
MHC2-6 MHCA2-6 Model (2) (1) Cylinder bore (mm) MHCA2-6 Axial ported (With hose nipple) Opening/Closing angle (Both sides) Mass (g) Action Model Gripping moment (Effective value) Nm MHC2-6D MHCA2-6D MHC2-6S MHCA2-6S 22 19 22 19 6 6 6 6 Double acting 30 to 10 0.038 30 to 10 Single acting (Normally open) JIS Symbol Double acting 0.024 Note 1) At the pressure of 0.5 MPa Note 2) Excluding the