The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes

The LEYG guided rod electric actuator pairs a LEY actuator with a bolt-on bearing block with double guide rods.  The guide rods counter rotational forces instead of the drive and motor, and also resist shock and sustained lateral loads.  Guide selection offers either slide or ball bushing bearings.  The motor orientation can be reverse mounted on top for compact length, or inline for compact

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Electric Actuator New New Rod Type Guide Rod Type Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Rod Type Series LEY Size: 16, 25, 32 Long stroke: Max.500 mm (LEY32) New Mounting variations N Direct mounting: 3 directions, Bracket mounting: 3 types N Auto switch can be mounted. N Speed control/Positioning: Max. 64 points N Either positioning or pushing control can be selected. Possible

Size: 32, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CE1 (EtherCAT®), Mounting: 8 (DIN Rail)

Size: 32, Bearing Type: Ball Bushing Bearing, Motor Mounting Position: Top Mounting, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Guide Option: w/o Option, Actuator Cable Type, Length: 5m, Controller: EtherCAT®, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes

Bending value (Reference) 20 Complies with FDA (Food and Drug Administration) 177-1550 Operating temperature Air, Inert gas: 20 to 200C, Water: 0 to 100C (No freezing) dissolution test.

Heater assembly quantity 200/40 200/50 400/100 600/150 800/220 1200/350 100V H4 100C Heater assembly quantity used Heater power W (Nominal value) In-rush/Power consumption (Option symbolOperating voltage) 800/40 800/50 1600/100 2400/150 3200/220 4800/350 200V 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. 3 pcs. 4 pcs.

None H0 High temp. type With heater for 80C (176F) H1 5 to 150C (41 to 302F) H2 With heater for 100C (212F) H3 With heater for 120C (248F) Option specifications/Combination table Option specifications Symbol Model XLF-16 XLF-25 XLF-40 XLF-50 XLF-63 XLF-80 A Indicator H0 Without heater High temp. type H1 With heater for 80C (176F) H2 With heater for 100C (212F) H3 With heater for 120C (248F

None H0 High temp. type With heater for 80C (176F) H1 5 to 150C (41 to 302F) H2 With heater for 100C (212F) H3 With heater for 120C (248F) Option specifications/Combination table Option specifications Symbol Model XLF-16 XLF-25 XLF-40 XLF-50 XLF-63 XLF-80 A Indicator H0 Without heater High temp. type H1 With heater for 80C (176F) H2 With heater for 100C (212F) H3 With heater for 120C (248F

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

One-touch fittings, Insert fittings Fluoropolymer fittings: LQ series Note 3) Applicable Note 2) fittings Miniature fittings: M, MS series (Hose nipple type) 20C 0.7 0.25 0.1 Refer to the max. operating pressure curve. 1 0.4 0.2 0.7 0.25 0.1 1 0.4 0.2 1.5 0.55 0.3 1.7 0.6 0.3 2.3 0.85 0.4 100C Max. operating pressure (MPa) 200C How to measure the minimum bending radius.

-X7 Angle adjusting screw "B" Angle adjusting screw "A" Rotation at 90 Heat resistant In this rotary actuator, the material of the seals has been changed to the heat resistant type (to withstand up to 100C), for applications in environments that exceed the standard specification temperatures of 0 to 60C.

End plate Symbol 12 -X2128 Heat-resistant Specification (10 to 100C) Seal material and grease have been changed so that the product can be used at temperatures between 10 up to 100C. Specifications Ambient temperature 10C to 100C (No freezing) Seal material Fluororubber MXQ X2128 Standard model no.