LEY*G is a high performance version of the standard rod actuator, suitable for push, pull, lift and press applications. Cycle time is dramatically reduced by a combination of higher maximum speed and acceleration/deceleration. Speed gains are 20-60% faster, depending on motor size, ballscrew pitch, and stroke. The 24VDC motor also includes a battery-less absolute encoder, allowing the actuator
Electric Actuator New New Rod Type Guide Rod Type Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Rod Type Series LEY Size: 16, 25, 32 Long stroke: Max.500 mm (LEY32) New Mounting variations N Direct mounting: 3 directions, Bracket mounting: 3 types N Auto switch can be mounted. N Speed control/Positioning: Max. 64 points N Either positioning or pushing control can be selected. Possible
Series: LEY, Size: 40, Motor Mounting Position: D (In-line), Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm), Stroke: 50mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: R5 (5m), Controller
Series: LEY, Size: 40, Motor Mounting Position: D (In-line), Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End, Male Thread; 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type
Series: LEY, Size: 40, Motor Mounting Position: In-line, Motor Type: High Performance Battery-less Absolute, Step Motor, 24 VDC, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm, Stroke: 50mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: 5m, Controller: EhterNet/IPâ„¢, Controller
Series: LEY, Size: 40, Motor Mounting Position: In-line, Motor Type: High Performance Battery-less Absolute, Step Motor, 24 VDC, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 40: 4mm, Stroke: 200mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End, Male Thread; 1 Rod End Nut is Included, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: 5m, Controller
-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) * Not available with switch & with air cushion VMounted on the product. vPlease order separately.
(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.
Symbol Nil None A B C Changed part XVD Without indicator With indicator Without indicator With indicator XLF100-30-1 XLF100A-30-1 XLF100-30-1H XLF100A-30-1H 5 to 60C 8-1 8-2 XGT 8-1 5 to 150C 8-2 Temperature specifications Symbol Nil 5 to 60C 5 to 150C H0 CYV Temperature Seal material: Same as the seal materials of How to Order Valve Same as How to Order Specifications Valve type Shaft seal
Nominal filtration rating: 0.01 m [Filtration efficiency: 99.9%] Oil mist density at outlet: Max. 0.1 mg/m3 (ANR) [0.08 ppm] 150C 1/8, 1/4 200 250C 1/4, 3/8 500 350C 3/8, 1/2 1,000 Piping support type 450C AMH 1/2, 3/4 2,000 550C 3/4, 1 3,700 1, 1 1/2 650 6,000 1 1/2, 2 850 12,000 AMH150C to 550C AMH650/850 150C 1/8, 1/4 200 Dust filtration, Oil mist adsorption Dust filtration, Oil mist adsorption
cylinder can create a gas that is hazardous to humans. 1729 C Made to Order Common Specifications: -XB6: Heat Resistant Cylinder (10 to 150C) Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 2 CY3B series How to Order Temperature Range for Operating Cylinder and Piston Speed 1.
) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm SMC test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm P/A test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.
) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.
(Except swivel elbow) Fluid temperature: 65 to 260C (Swivel elbow: 5 to 150C) Grease-free, Can be used with steam. Applicable tubing O.D.
Symbol Heat Resistant Cylinder (10 to 150C) -XB6 The seal material and grease for air cylinders have been changed for high temperature tolerance, now with a range of 10 to 150C.
Symbol 1 Heat Resistant Cylinder (10 to 150C) -XB6 Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C.