As W = 50 < Wmax = 500, the selected model W Wmax can be used.
LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.
LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds 0.5 to 5.0 the set value.
Specifications 3. 1 Card Motor (1) Card Motor specifications Model LAT3-10 LAT3F-10 LAT3-20 LAT3F-20 LAT3-30 LAT3F-30 LAT3M-50 LAT3F-50 Stroke [mm] 10 20 30 50 Type Moving magnet type linear motor Maximum instantaneous thrust [N] Note 1) Note 2) Note 3) 5.2 6 5.5 2.5 Motor Continuous thrust [N] 3 2.8 2.6 1.5 Note 1) Note 2) Note 3) Type Linear guide with circulating balls Horizontal: 1000