LAT3-10 LAT3F-10 LAT3-20 LAT3F-20 LAT3-30 LAT3F-30 5 10 20 30 Model Stroke [mm] Positioning repeatability [m] 90 5 90 5 90 Check the load mass and load factor. 3 From Fig. 2: = 0, find Wmax = 500 As W = 200 < Wmax = 500, the selected model can be used. Fig.2 Wmax Find the allowable load mass Wmax [g] from the graph.
Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right. LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.
Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right. LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds 0.5 to 5.0 the set value.
Specifications 3. 1 Card Motor (1) Card Motor specifications Model LAT3-10 LAT3F-10 LAT3-20 LAT3F-20 LAT3-30 LAT3F-30 LAT3M-50 LAT3F-50 Stroke [mm] 10 20 30 50 Type Moving magnet type linear motor Maximum instantaneous thrust [N] Note 1) Note 2) Note 3) 5.2 6 5.5 2.5 Motor Continuous thrust [N] 3 2.8 2.6 1.5 Note 1) Note 2) Note 3) Type Linear guide with circulating balls Horizontal: 1000