The JXC*1 is a single axis controller for LE's 24VDC step motors compatible with serveral fieldbus protocols including Ethernet/IP fieldbus. Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible over the network. Futher Ethernet/IP capable functions include return to origin, alarm outputs and resets, parameter setup, status monitoring
Similar items in stock.
Axis mode (mm/s) (mm) Selection (mm) (mm) 2) 2) (mm/s (mm/s (mm) 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 -41- () () (TB) No. Step No. 063 No. TB PLC 0 No.
Vertical Mounting, Ball Bushing Bearing r Over 40 mm stroke e 35 mm stroke or less 100 100 LEYG32L LEYG32L Load mass m [kg] Load mass m [kg] 10 10 LEYG25L LEYG25L 1 1 0.1 0.1 1000 1000 10 100 10 100 Eccentric distance L [mm] Eccentric distance L [mm] * The limit of vertical load mass varies depending on lead and speed.
300 200 Lead 8: LEY32DB 200 100 Lead 16: LEY32DA 100 Lead 20: LEY32A 0 60 30 120 90 0 60 30 120 90 Ratio to rated torque [%] Ratio to rated torque [%] * When using the force control or speed control, set the maximum value to be no more than 90% of the rated torque.