The JXC*1 is a single axis controller for LE's 24VDC step motors compatible with several fieldbus protocols including Ethernet/IP fieldbus. Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible over the network. Futher fieldbus compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring
Similar items in stock.
Movement Speed Position Acceleration Deceleration Area 1 Area 2 In pos force Force speed force 2 2 mode mm/s mm mm/s mm/s mm mm mm Value mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () (1)No.
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
Protocol: E (EtherCAT®), Mounting: 8 (DIN Rail), Cable Connector: None, Actuator: LESYH, Body Size: 8, Motor Mounting: D2 (In-line Cover Right), Lead: C (8: 2.5mm), Stroke: 50mm
Protocol: EtherCAT®, Mounting: DIN Rail, Cable Connector: None, Actuator: LESYH, Body Size: 8, Motor Mounting: In-line Cover Right, Lead: 8: 2.5mm, Stroke: 50mm