The JXC*1 is a single axis controller for LE's 24VDC step motors compatible with several fieldbus protocols including Ethernet/IP fieldbus. Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible over the network. Futher fieldbus compatible functions include return to origin, alarm outputs and resets, parameter setup, status monitoring
Similar items in stock.
Movement Speed Position Acceleration Deceleration Area 1 Area 2 In pos force Force speed force 2 2 mode mm/s mm mm/s mm/s mm mm mm Value mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () (1)No.
Body Size: 8, Type: D (In-line Motor Type), Motor: Step Motor (Servo DC24V), Lead Screw: K (Size 8: 4mm, Size 16: 5mm, Size 25: 8mm), Stroke: 50mm
Body Size: 8, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: -, Body Option: -, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC: -
Protocol: EtherNet/IPâ„¢, Mounting: DIN Rail Mounting, Cable Connector: w/o Plug Connector, Actuator: LESH, Body Size: 8, Motor Mounting: In-line Motor Type, Lead: LES8: 4mm; LES16: 5mm; LES25: 8mm, Stroke: 50mm