The JXC*1 is a single axis controller for LE's 24VDC step motors with absolute encoders, compatible with several fieldbus protocols including Ethernet/IP™ fieldbus. Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible over the network. Futher fieldbus
Similar items in stock.
Movement Speed Position Acceleration Deceleration Area 1 Area 2 In pos force Force speed force 2 2 mode mm/s mm mm/s mm/s mm mm mm Value mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () (1)No.
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
Series: LEFS, Accuracy: Basic Type, Size: 25, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 50mm
Series: LEFS, Accuracy: Basic Type, Size: 25, Motor Mounting Position: Right Side Parallel, Motor Type: Battery-less absolute, 24VDC, Step, Lead: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm, Stroke: 50mm, Motor Option: -, Auto Switch Compatibility: -, Grease Application: -, Positioning Pin Hole: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication