The JXC51 and JXC61 are controllers for LE's 24VDC step motors with the batteryless absolute encoders. Enter up to 64 motion control step data with position, speed, accelertion, and pushing force so they can be called in any sequence by the PLC using the parallel I/O interface. Data entry requires laptop software or a teaching pendant. An Easy mode for data entry is available for quick start
Similar items in stock.
0.000 20 40 60 0.000 25 50 75 100 125 Load [N] Load [N] Load [N] LESYH16 LESYH16 Lr = 120 mm LESYH16 0.50 0.3 0.08 Table displacement [mm] Table displacement [mm] Table displacement [mm] LESYH16 -100 LESYH16 -100 LESYH16 -100 0.40 0.06 0.2 0.30 LESYH16 -50 0.04 LESYH16 -50 0.20 LESYH16 -50 0.1 0.02 0.10 0.000 100 200 300 400 0.000 50 100 150 200 0.00 50 100 150 200 Load [N] Load [N] Load
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
Series: LEFS, Accuracy: Basic Type, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 50mm