Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. The units are compact, lightweight, and include an easy to read LED display. Input signals can be analog current or voltage, 4 or 16 point presets, or a range of communication protocols including CC-Link, DeviceNet™, PROFIBUS, RS-232C or I/O-Link
For example, in the case of ITV2050 (0.9 MPa), a 50% input (0.45 MPa) creates a detectable range of 0.36 to 0.54 MPa. Set pressure ITV ITV 10% IC 5 sec. ITVX ON OFF Alarm output PVQ 0 100 Input signal (% F.S.) VEF VEP Figure 1. Alarm output range Figure 2.
Doc. No. ITV2-OM00109-C P R O D U C T N A M E E/P Regulator (16points preset input type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-52* Series (Switch output: NPN output) ITV1000/2000/3000/2090-53* Series (Switch output: PNP output) Install and operate the product only after reading the Operation Manual carefully and understanding its contents. Specifically, read the safety instructions