This next generation ISE70 pressure sensor provides continuous quantitative values, as well as switched digital outputs when pressure set points are met. This sensor is also IO-Link compatible. Sensor information, such as identity, functional state, cable connection, and current or switch values can be set or monitored remotely though an IO-Link master, and connected to a fieldbus network
Description Nil None 1 ISO 1179-1 compliant A Bracket A (Interchangeable with ISE70) Output specification1 Symbol Description B Bracket B L2 IO-Link: Switch output 1 + Switch output 2 (Switch output: NPN or PNP switching type) Option 1 1 Refer to pages 7 and 10 for details.
If a commercial switching regulator is used, make sure that the F.G. terminal is grounded. 1. Connecting the pipe to the switch When connecting the pipe to the switch, apply a torque of 13.6 Nm or greater for the ISE70 series and a torque of 25 Nm or greater for the ISE75/75H series. 2.
Bracket A (Part No.: ZS-50-A) Bracket B (Part No.: ZS-50-B) -13No.PS-OMW0002-C Piping Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm. Piping specification: -F02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting.