A large digital display provides a clear view of the current and set values. 

HRSH Air-cooled recirculating chillers offer a cooling capacity range of 10.5 to 28 kW. Coolant and refrigeration circuits are included in a compact and lightweight package. Extracted heat is air cooled. An inverter provides demand-based rotation control for the compressor, pump and fan, offering substantial energy savings. Electric options ensure global power supply compatibility. Additional

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Specications Model HRSH100-Al-20-l HRSH150-Al-20-l HRSH200-Al-20-l HRSH250-Al-20-l HRSH300-Al-20-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.27 2.1 2.1 2.8 2.8 Control method PID control Ambient temperature/Altitude Note 1), 9) C Temperature: 20 to 45, Altitude: less than 3000

Model HRS012-A-20 HRS012-W-20 HRS018-A-20 HRS018-W-20 Air-cooled refrigeration Water-cooled refrigeration HRS024-A-20 Air-cooled refrigeration HRS024-W-20 Water-cooled refrigeration HRS050-A-20 Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration R410A (HFC) R407C (HFC) PID control Temperature

HRSH250/300-A-20-, HRSH250/300-A-40. 8-9 8.2.4 HRSH100/150/200/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200

IDF6E-20 IDF8E-20, IDF11E-20 (mm) Dimensions 5 A IDU3E-20, IDU4E-20 IDU6E-20, IDU8E-20, IDU11E-20 A B C D E F Model IDF22E-20 IDF37E-20 IDF22E-30 IDF37E-30 IDF55E-30 IDF75E-30 IDU22E-30 IDU37E-30 IDU55E-30 IDU75E-30 59 40 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 30 mA 25 46 125 10 A 60 39 200 V type 60 81 148 50 36 73 133 IDF75E

Applicable model -A -W HRSH100--20-S HRSH150--20-S HRSH200--20-S HRSH250--20-S HRSH300-A-20-S HEB HED HEA IDH 179 HRSH Series Optional Accessories q Piping Conversion Fitting This is a fitting to change the port from Rc to G or NPT.

-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

-A/W-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH100-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb