HRS compact recirculating chillers are designed to meet the widest range of single-point applications in both industrial and technology settings. The package design is robust enough for the factory, yet ergonomic and compact for lab installations. Coolant can be either heated or cooled within the set temperature range. Choose from six cooling capacities, air or water cooled refrigerant, and
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
Lifting height [m] Pressure [MPa] Lifting height [m] Circulating fluid flow rate [LPM] Circulating fluid flow rate [LPM] Required Facility Water Flow Rate HRS050-A-20 (Single-phase 200 to 230 VAC) 0.5 10 20 10 20 50 HRS012-W, HRS018-W, HRS024-W-20 Outlet 60 [Hz] 0.4 40 Facility water flow rate [L/min] 30 0.3 30 25 Outlet 60 [Hz] HRS024-W-20 20 0.2 20 10 20 HRS018-W15 10 0.1 Return port 10
Use the connector included as an accessory.
) Note 10) Note 10) Note 10) Note 10) Note 10) use pressure within the specification range.
HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water
/030-A-20-R . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS018-A-20--R . 9-7 9.4.2 HRS030-A-20--R . 9-7 9.5 Heating capacity . 9-8 9.5.1 HRS018-A-20-R, HRS030-A-20-R . 9-8 9.6 Pump capacity. 9-9 9.6.1 HRS018-A-20-R, HRS030-A-20-R . 9-9 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R . 9-9 9.7 Compliance . 9-10 9.8 Sample DoC. . 9-11 9.9 Daily Check Sheet . 9-12 Chapter 10 Product Warranty . 10-1 HRS-R
(In such a case, use a bypass piping set (sold separately).) 8 Purchase an earth leakage breaker with current sensitivity of 30 mA separately. 9 Front: 1 m, height: 1 m, stable with no load, Other conditions See 3. 10 Weight in the dry state without circulating uids 9
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: -
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-lift Pump)
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: High pump head specification
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BT ( B + T)