The heart of the Air Management System is the hub. Based on the PF3A flow sensor, the hub generates flow, pressure and temperature data to quantify machine operation. The standalone or remote hubs can communicate wirelessly with the base units. The base units have fieldbus communication for connection to the PLC while process data is provided via OPC UA to the customer analytics system.<
-EC-M zx1-DR1-4 sra.3-4) NZXi071-EC-M zxl-DR16-4 NZZXl04-TB-A r:::r:l::t: l:l:l:lrrl:l:l:l :r:t:41:1it!
-EC-M zx1-DR1-4 sra.3-4) NZXi071-EC-M zxl-DR16-4 NZZXl04-TB-A r:::r:l::t: l:l:l:lrrl:l:l:l :r:t:41:1it!
60 40 40 40 40 27 27 27 40 27 Suction flow rate Suction flow rate Suction flow rate Suction flow rate 20 13 13 13 13 20 0 60 40 20 0.6 0.3 0.5 0.4 0.2 0 0.1 0 60 40 20 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure (MPa) Flow rate (l/min (ANR)) Supply pressure (MPa) Flow rate (l/min (ANR)) 13-4-26 7 Series ZM Vacuum Ejector: With Solid State Timer Exhaust Characteristics/Flow Characteristics,
28 1 40 27 115 100 62 3/4 180.5 124.9 135 CCVL1-G-S 66 107 116 50 24 40 28 2 40 27 100 80 3/4 135 180.5 132.8 135 M6 x 1 10.5 to 12.5 CCVL2-G-S 66 107 116 50 24 40 28 1 40 27 115 100 80 3/4 135 180.5 124.9 135 CCVL3-G-S 66 66 107 107 116 116 50 50 24 40 28 28 1 40 40 27 27 115 115 100 100 80 80 3/4 135 135 180.5 124.9 135 CCVL0-S 3/4 Pitch of mounting on the wall is CA and
x 1.5 Up to 700 1/8 146 9 10 40 40 60 196 206 20 42.5 40 32 M26 x 1.5 Up to 1000 1/8 159 9 10 40 60 209 219 22 40 51 M32 x 2 53 Up to 1000 1/4 181 10 11 53 77 236.5 247 26.5 The dimension NA(42.5) is wider than dimension TX(40).
Body Size: 20, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (Units Selection Function)
Body Size: 60, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (Units Selection Function)
Body Size: 30, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (Units Selection Function)
Body Size: 20, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: Units Selection Function
Body Size: 60, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: Units Selection Function
Body Size: 30, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: Units Selection Function
(page 141) -142No.PF-OMA1007-B Air Management Hub Base type EXA1-20/30/40-PN/EN/EC-# Model A B C D E F EXA1-20 236.2 35 42 19.1 65.1 30.5 EXA1-30 236.2 43 53 13.6 65.1 30.5 EXA1-40 240.4 51 64.4 4.6 71 35.5 -143No.PF-OMA1007-B EXA1-60-PN/EN/EC-# -144No.PF-OMA1007-B Remote type EXA1-20/30/40-SA-# Model A B C D E F G EXA1-20 236.2 35 42 19.1 65.1 30.5 74.7 EXA1-30 236.2 43 53 13.6 65.1 30.5
Body Size: 40, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (Units Selection Function)
Body Size: 40, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (Units Selection Function)
Body Size: 40, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (Units Selection Function)
Body Size: 40, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: Units Selection Function
Body Size: 40, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: Units Selection Function