SMC Corporation of America
Elite Part Number Search
Search Results "EX260-SEN3"
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .44092 lb

EX260 series is a compact and cost effective fieldbus solution for output applicable to SMC's most popular directional control valves such as New SY, SV, VQC, and S0700 Series. It can control up to 32 solenoids in one manifold. Available protocols are EtherNet/IP™, PROFINET®, EtherCATConfigure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

SI Unit Integrated-type/For Output Series EX260 Note) RoHS Compact design Compact design for space saving Number of outputs Each 32/16 digital output type available in the series Output polarity Each negative common (PNP) / positive common (NPN) type available in the series Enclosure IP67 (For units with D-sub connector, and when connected with S0700 manifolds, it is IP40.)

SI Unit Specifications Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4 PROFIBUS DP DeviceNet CC-Link Protocol Applicable system Volume 1(Edition 3.5) Volume 3(Edition 1.5) DP-V0 Ver.1.10 Version Note 1) GSD file EDS file Configuration file Note 3) SMJ1: 32/32 SMJ3: 32/32 (1 station, remote I/O stations) SMJ2: 32/32 SMJ4: 32/32

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., "SI UNIT, EX, SERIAL TRANSMISSION SYSTEM, N lb

EDS file Product number File name Contents (EDS file and icon) 1 EX260-SEN1 ex260_sen1_24_v.zip ex260_sen1_24_v.eds ex260-sen1.ico 2 EX260-SEN2 ex260_sen2_24_v.zip ex260_sen2_24_v.eds ex260-sen2.ico 3 EX260-SEN3 ex260_sen3_22_v.zip ex260_sen3_22_v.eds ex260-sen3.ico 4 EX260-SEN4 ex260_sen4_22_v.zip ex260_sen4_22_v.eds ex260-sen4.ico Setting using RSLogix5000TM The method of connecting the

EtherCAT 32 EX260-SEC1 EX260-SEC2 M12 SDB 16 EX260-SEC3 EX260-SEC4 SFA PROFINET 32 EX260-SPN1 EX260-SPN2 M12 SFB 16 EX260-SPN3 EX260-SPN4 SEA EtherNet/IP32 EX260-SEN1 EX260-SEN2 M12 SEB 16 EX260-SEN3 EX260-SEN4 SDTA AS-Interface, Negative common (PNP), (8 in/8 out, 31 slave modes, 2 power supply systems) EX250-SAS3 PROFIBUS DP VQC 4/5 VQC 4/5 SDTB AS-Interface, Negative common (PNP), (4

Please download the Operation Manual via SMC website, http://www.smcworld.com PROFINET M12 16 EX260-SPN4 EX260-SPN3 32 EX260-SEN2 EX260-SEN1 EtherNet/IP M12 16 EX260-SEN4 EX260-SEN3 Note) When the communication connector specification is D-sub, the enclosure is IP40.

EX260-SDN1 EX260-SDN2 EX260-SDN3 EX260-SDN4 EX260-SPR1 EX260-SPR2 EX260-SPR3 EX260-SPR4 EX260-SPR5 EX260-SPR6 EX260-SPR7 EX260-SPR8 EX260-SMJ1 EX260-SMJ2 EX260-SMJ3 EX260-SMJ4 EX260-SEC1 EX260-SEC2 EX260-SEC3 EX260-SEC4 EX260-SPN1 EX260-SPN2 EX260-SPN3 EX260-SPN4 EX250-SDN1 EX250-SPR1 EX250-SMJ2 EX250-SAS3 EX250-SAS5 EX250-SAS7 EX250-SAS9 EX250-SCA1A EX250-SEN1 EX250-IE1 EX250-IE2 EX250-IE3

SI Unit Specifications Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4 PROFIBUS DP DeviceNet CC-Link Protocol Applicable system Volume 1(Edition 3.5) Volume 3(Edition 1.5) DP-V0 Ver.1.10 Version Note 1) GSD file EDS file Configuration file Note 3) SMJ1: 32/32 SMJ3: 32/32 (1 station, remote I/O stations) SMJ2: 32/32 SMJ4: 32/32

SI Unit Specifications Model EX260-SPR1/3 EX260-SPR2/4 EX260-SPR5/7 EX260-SPR6/8 EX260-SDN1/3 EX260-SDN2/4 EX260-SMJ1/3 EX260-SMJ2/4 PROFIBUS DP DeviceNet CC-Link Protocol Applicable system Volume 1(Edition 3.5) Volume 3(Edition 1.5) DP-V0 Ver.1.10 Version Note 1) GSD file EDS file Configuration file Note 3) SMJ1: 32/32 SMJ3: 32/32 (1 station, remote I/O stations) SMJ2: 32/32 SMJ4: 32/32

-SDN1, EX260-SDN3, EX260-SMJ1, EX260-SMJ3, EX260-SPR1, EX260-SPR3, EX260-SPR5, EX260-SPR7, EX260-SEN1, EX260-SEN3, EX260-SEC1, EX260-SEC3, EX260-SPL1, EX260-SPL3, EX500-Q102, EX500-S103 EX9-OET1, EX9-OEP1 EX126D-SMJ1 EX250-SMJ2 EX260-SDN2, EX260-SDN4, EX260-SMJ2, EX260-SMJ4, EX260-SPR2, EX260-SPR4, EX260-SPR6, EX260-SPR8, EX260-SEN2, EX260-SEN4, EX260-SEC2, EX260-SEC4 EX500-Q002 EX9-OET2,

How to import the IODD file of the SMC EX260-SIL1 is shown below. The IODD file can be downloaded from the URL below.

EtherNet/IPTM is a trademark of ODVA. 2012 SMC Corporation All Rights Reserved 3 EX260-SEN3 ex260_sen3_22_v**.eds 4 ex260_sen4_22_v**.eds EX260-SEN4

PC (Commercially available product) Switching hub (Unmanaged switch) LAN cable EX600-SEN3 IP address setting (example): Device IP address Subnet mask PC 192.168.0.253 255.255.255.0 EX260-SEN1 192.168.0.10 EX600-SEN3 192.168.0.11 Fig. Network Configuration Example -4No.EX-OMV1026-B 4. Setting the EtherNet/IPTM Device No.

SI Unit (Safety Communication) EX260 PS1 F Series Part no.

Connecting to a EX600-SEN3 (Ex. Windows 10) (1) Open a web browser on the PC. (2) Type the IP address of EX600-SEN3. (Ex. http://192.168.0.1) (3) The EX600 webpage should load after several seconds. NOTE Connect one SI unit to one PC. Default setting Password: admin When [Login] is selected after inputting Password, the screen is switched to [Admin mode].

(8/8 ) 1 1 EX600-DMF (8/8 ) 1 1 EX600-AXA 4 (2 byte/1 ) 0 (2 ) EX600-AYA (2 ) 0 4 (2 byte/1 ) EX600-AMB 4 4 (2/2 ) (2 byte/1 ) (2 byte/1 ) -58No.EX-OMS0026CN 2 EX600 0 1 2 1 <1> 0 1 DYB SEN3 SI 4 byte 1 byte [0](EX600-DYB)1 byte [1]SI (EX600-SEN3)4 byte 0 Padding DYB(0) 07 Byte0 Byte1 07 Byte2 815 SEN3(1) Byte3 1623 Byte4 2431 Byte5 Padding 2 byte 6 byte 1 Byte0 byte0 DYB(0)

Unit 0 Unit 1 DYB Digital output unit 1 byte output SEN3 SI unit 4 bytes output End plate Valve Input data: None Output data: (Unit 0) Digital output Unit (EX600-DYB): 1 byte occupied (Unit 1) SI Unit (EX600-SEN3): 4 bytes occupied When Diagnostic mode 0 is selected Input data Output data Byte0 DYB (Unit 0) Output 0 to 7 Byte1 Padding data Output 0 to 7 Byte2 Output 8 to 15 SEN3