The CE1 series is a stroke reading cylinder with position feedback. The home position can be anywhere within the cylinder stroke. Measurement is possible throughout the full stroke range. The CE1 series is offered in 6 bore sizes and is auto switch capable.
V Yes IC circuit Relay, PLC No 100 V or less 100 V, 200 V 2-wire 24 V PLC Terminal conduit 12 V Yes Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indicator) Solid state auto switches marked with are produced upon receipt of order.
500 400 300 200 100 100 500 400 300 200 100 MNB Maximum speed: V (mm/s) Maximum speed: V (mm/s) CNA Graph 6 Graph 3 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa CNS 4000 2000 250 3000 CLS 250 200 2000 180 1000 CLQ 700 800 900 160 200 140 Load mass: m (kg) Load mass: m (kg) 180 1000 RLQ 700 800 900 600 125 160 500 MLU 600 140 400 500 125 400 MLGP 300 300 ML1C 200 200 [Example] 100 100 100 500
The cylinder section does not have a water resistant enclosure. 3-3 Allowable Kinetic Energy 3-3-1 Allowable Kinetic Energy (J) Bore size(mm) 12 20 32 40 50 63 Allowable Kinetic EnergyE 0.022 0.055 0.15 0.26 0.46 0.77 3-3-2 Mass of Cylinder Movable Parts (g) Cylinder stroke (mm) Bore size(mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 28 33 38 43 48 53 20 70 84 98 112 126 140 154 168