The AS speed controller variants with indicator window allow for numerical verification of flow rate setting.
Note 1) Inch size Note 3) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Metric size 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Indicator window direction Elbow Universal Nil 0 Indicator window Note 1) For selecting applicable tubing O.D., refer to the Model on page 4. Note 2) Use 1/8" tubing.
3 O-ring NBR u 15-9-105 Dimensions L4 D3 H (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions AS120-U10/32-T 10-32 UNF 10-32 UNF AS120-M5-T M5 x 0.8 M5 x 0.8 Model T2 H D1 T1 D2 D3 L1 L2 L3 L4 A 8 9 9 4.5 10 31 10.3 0.7 27.4 AS220-N01-ST NPT 1/8 NPT 1/8 AS220-F01-ST G 1/8 AS220-01-ST Rc 1/8 R 1/8 12 14.3 14.6 7 18 35.6
Doc. no. AS*-OMA0069-D PRODUCT NAME SPEED CONTROLLER STANDARD TYPE IN-LINE TYPE MODEL/ Series/ Product Number / / / Contents 1Safety Instructions 2 3 2Specific Product Precautions 4 5 3Application 6 4Specifications 6 5Malfunctions and Countermeasures 6 6Construction 7 8 -1- Speed Controller Standard Type In-Line Type / AS Series Safety Instructions These safety instructions are intended