Where finite adjustment is required to control actuators at very low speeds such as handling fragile material or smooth process control, the “-FM” series has been designed exclusively to meet this requirement. Effective orifice area has been reduced to 1/10th of standard series, but still retains 10 turns of the adjustment needle, (20 turns on the M5 size). This series comes complete with
AS-FM Series Speed Controller for Low Speed Operation with One-touch Fitting Elbow Type/Universal Type (Resin Body) How to Order AS 2 2 0 1 F M 01 06 Lock nut option Nil J Hexagon lock nut Round lock nut AS-F Body size TMH 1 2 M5 standard 1/8, 1/4 standard Made to Order Refer to the below for details.
Speed Controller: Standard Type Series AS In-line Type Model/Flow Rate and Effective Area Compact size saves space. Speed may be accurately controlled even at low speeds. Constant speed easily set. Retainer prevents an accidental loss of needle. Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow
Doc. no. AS*-OMA0069-D PRODUCT NAME SPEED CONTROLLER STANDARD TYPE IN-LINE TYPE MODEL/ Series/ Product Number / / / Contents 1Safety Instructions 2 3 2Specific Product Precautions 4 5 3Application 6 4Specifications 6 5Malfunctions and Countermeasures 6 6Construction 7 8 -1- Speed Controller Standard Type In-Line Type / AS Series Safety Instructions These safety instructions are intended