AKP series Compact Pilot Check Valve designed as drop prevention when supply air is lost. It will also provide temporary intermediate stop. AKP series provides flexibility in piping orientations and it allows installation in multiple positions and in tight spaces. AKP series is available as pilot check valve and combination of pilot check valve with residual pressure release. AKP series
Check Valve Series AK Large flow capacity Low cracking pressure: 0.02 MPa A wide variation of models Model Model Effective area (mm2) Port size Weight (g) 1 8 AK2000-01 25 105 1 4 AK2000-02 27.5 100 1 4 AK4000-02 47 155 3 8 AK4000-03 85 150 1 2 AK4000-04 95 140 3 4 AK6000-06 200 345 AK6000-10 230 315 1 Specifications AS Fluid Air Proof pressure 1.5 MPa ASP Maximum operating pressure 1 MPa
Model AKH03-U10/32 AKH03-N01S AKH07-U10/32 AKH07-N01S AKH07-N02S AKH09-N01S AKH09-N02S AKH09-N03S AKH11-N02S AKH11-N03S AKH11-N04S AKH13-N03S AKH13-N04S 8 11.11 10-32 UNF 1/8 10-32 UNF 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 3/8 1/2 24.3 24.6 25.8 26.9 31 31.7 21.2 20.6 22.7 22.9 25 27.7 36 35.5 48.3 40.7 41.2 54 46.5 5 10 10 11 18 16 24 43 47 40 79 87 85 Applicable tubing 5/32 2.8 12.7 2.8 6.5 6.5
Construction Vertical Type Elbow Type Vertical Type Universal Type Seal methodFace seal For G thread Seal methodFace seal For G thread Without Exhaust Without Exhaust AKP-UA**(E)-G* AKP-LA**(E)-G* With Exhaust With Exhaust Horizontal Type Elbow Type Horizontal Type Universal Type Seal methodFace seal For G thread Seal methodFace seal For G thread With Exhaust With Exhaust AKP-UB**(E)-G* AKP-LB