Smart positioners are designed to be paired with process control valves. Additionally, the 52-versions comply with ATEX directive category 1 as intrinsically safe and explosion proof. Two temperature classes are available, including T4/T5, or T6. The IP8001 lever type is for stem type valves, typically with diaphragm actuators. The IP8101 rotary type is for rotary valves with oscillating actuators
Applicable thread Gasket M-3G2 M3 M-5G2 M5 M-6G M6 Brass Description Part no.
Standard lead wire length is 0.5 m. Add L to the end of the part number when 3 m is desired, M when 1 m, and Z when 5 m. Ex.)
When pressure is applied to the pilot port M, the valve M is removed from the body seat surface and fully opens. 4 2 0 [4] Closing of the initial exhaust valve, the main exhaust valve By removing the pressure from the pilot ports S and M, both valves return to their sealed position. 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.4 4.0 4.5 5.0 5.5 6.0 Adjustment nut rotations n 9 Series XMD, XYD Dimensions