SMC Corporation of America
Elite Part Number Search
Search Results "25A-MGPM16-125Z-M9BL"
The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.  The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing

The MGP is a compact body actuator integrated with internal guide shafts to isolate the load bearing from the movement of the actuator's rod and seals.  The carbon steel alloy slide bearing (Type M) provides lateral stability protecting it from side load impacts, suitable for stopping applications.  The high precision ball bushing (Type L) allows for smooth operation that ensures

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

New New Compact Guide Cylinder (Basic type) 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 Weight reduced by up to 17% with a shorter guide rod and thinner plate Up to 17% 17% Weight reduced! Weight reduced! Guide rod shortened for MGPM40-25 stroke 22mm Max. Space required between the bottom of the cylinder body and your equipment is reduced. Space saving Space saving 3 types of bearing can be selected

SY3000 SY5000 SY7000 Standard (0.7 MPa) Quick response type (0.7 MPa) High pressure type (1.0 MPa) SY30V-25A Gasket SY50V-25A Only metal seal type is available for the high pressure type. (1.0 MPa) a-side pilot valve Pilot cover x 1 + B tight flat head screw x 1 Coil type Nil T w Standard With power saving circuit Pilot cover Socket q w Rated voltage 5 6 24 VDC 12 VDC b-side pilot valve

For details, refer to page 8-30-32. 8-19-36 Series MGP Compact Guide Cylinder With Air Cushion Construction (With air cushion) Series MGPM Series MGPL MGPM16 to 25 MGPL16 to 25 i q !5 u !4 !6 @5 @3 !9 w @7 !0 y !2 @5 !1 !7 @6 !0 r @4 e o t 16: 25 stroke MX 20, 25: 75 stroke or less !8 MTS !

For details, refer to page 126. 46 MXQA Series Dimensions: MXQ 25A [Standard] MXQ 25A-mZ Standard type *1 If long bolts are used, they may touch the guide block and cause a malfunction, etc. Use a screw which has an intermediate length between the maximum screw-in depth and minimum screw-in depth.

.: GR-S-010 (10 g) 126 A Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 16, 20, 25, 32, 40, 50, 63, 80, 100 P.333 Construction MGPM16 to 25 MGPM32 to 100 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.

2144 1429 7147 IN Note) Theoretical output (N) = Pressure (MPa) x Piston area (mm) 1mm = 0.0016in 1MPa = 145 psi 2 Compact Guide Cylinder Series MGP Weights Slide bearing: MGPM12 to 100 (kg) Bore size (mm) Standard stroke (mm) 10 Model 20 25 30 40 50 75 100 125 0.70 150 175 250 300 350 400 200 MGPM12 0.59 12 0.24 0.28 0.35 0.39 0.50 0.79 1.09 0.89 1.22 1.17 0.98 1.35 0.31 0.43 0.97 MGPM16

For details, refer to page 8-30-32. 8-19-36 Series MGP Compact Guide Cylinder With Air Cushion Construction (With air cushion) Series MGPM Series MGPL MGPM16 to 25 MGPL16 to 25 i q !5 u !4 !6 @5 @3 !9 w @7 !0 y !2 @5 !1 !7 @6 !0 r @4 e o t 16: 25 stroke MX 20, 25: 75 stroke or less !8 MTS !

to 25 (Slide Bearing) MGPM16 to 25 (Slide Bearing) 100 l @ 50mm l @ 50mm u u 25 m m 50 40 20 Transported object weight: m(kg) 30 16 20 10 *When requiring a bracket with a longer l dimension select a bore size large enough to accommodate the additional moment.

to 25 (Slide Bearing) MGPM16 to 25 (Slide Bearing) 100 L 50 mm L 50 mm 25 m m 50 40 20 Mass of transferred object: m [kg] 30 16 20 10 *: When selecting a model with a longer L dimension, be sure to choose a bore size which is sufficiently large. 4 5 Caution 3 Caution on handling 2 1.

MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32

CKG150-125Z/CKP150-125Z CKG163-125Z/CKP163-125Z Common CKG40-RZ125 CKQ CKG140-150Z CKG150-150Z/CKP150-150Z CKG163-150Z/CKP163-150Z Auto switch mounting bracket B CKG40-RZ150 CKG150-200Z/CKP150-200Z CKG163-200Z/CKP163-200Z CKG40-RZ200 D-M9/M9W D-M9A/A9 Switch mounting rod 2 Mount the part E of the auto switch mounting bracket so that it is in contact with the cylinder tube.

Special function Electrical entry Indicator light Wiring (Output) In-line Perpendicular 0.5 (Nil) 3 (L) DC AC 5 (Z) MHT Type 3-wire (NPN) 3-wire (PNP) 24 V MHY M9NV M9N Solid state switch 5 V IC circuit 12 V M9PV M9P Standard MHW Relay, PLC Grommet Yes M9BV M9B 2-wire 12 V Water resistant (2-color indication) MRHQ F9BA Lead wire length symbols: 0.5 m Nil (Example) M9B 3 m L (Example) M9BL

Bearing Style: Slide Bearing, Bore Size: 16mm, Port Type: Rc (Or M5x0.8 for 16 Bore), Stroke: 25mm, A: Air Cushion, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x

Bearing Type: M (Slide bearing), Bore Size: 16mm, Port Type: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 125mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x

.: GR-S-010 (10 g) 126 Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 16, 20, 25, 32, 40, 50, 63, 80, 100 P.333 Construction MGPM16 to 25 MGPM32 to 100 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.