10-VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor.
V 6 +5V 6 4 Shield ground 9 SIELD SQ Optical fiber (Reserve) 12 RTS Pin no. 3, 5, 7, 8, 10 and 11 marked with are open.
Clean Series: 10 (Clean Room), Actuation: 2 (2 Position Double), Seal Type: 1 (Rubber Seal), Function: Y (Low Wattage Type, 0.5W), Coil Voltage: 5 (24 VDC, w/Light/Surge voltage Suppressor), Manual Override: B (Locking Type, Tool Required)
Clean Series: Clean Room, Actuation: 2 Position Double, Seal Type: Rubber Seal, Function: Low Wattage Type, 0.5W, Coil Voltage: 24 VDC, w/Light/Surge voltage Suppressor, Manual Override: Locking Type, Tool Required
pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less, Ambient & fluid temperature: -10