ZSE20B(F)-L is a digital vacuum sensor with IO-Link communication protocol support. When paired with an IO-Link master, measured values, and settings can be accessed from the HMI screen of a PLC. ZSE20B(F)-L incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit and 13 bits for the measured value. The 3-screen, 3-color display
female thread ZS-46-A1 ZS-46-3L M5 Lead wire with connector (3-core, 2 m lead wire) A1 Bracket A (Vertical mounting) Piping port L Without waterproof cover R1/8 ZS-46-A2 01 For the lead wire with M12 connector, refer to p. 38.
Compact: Max. 17.5 mm shorter Lightweight: Max. 21 g lighter (When an M5 female thread is used.) (When an M5 female thread is used.)
IODD file 1 1 ISE20B-L(-M)SMC-ISE20B-L-ymmdd-IODD1.1 2 ISE20B-L-PSMC-ISE20B-L-P-ymmdd-IODD1.1 3 ZSE20B-L(-M)SMC-ZSE20B-L-ymmdd-IODD1.1 4 ZSE20B-L-PSMC-ZSE20B-L-P-ymmdd-IODD1.1 5 ZSE20BF-L(-M)SMC-ZSE20BF-L-ymmdd-IODD1.1 6 ZSE20BF-L-PSMC-ZSE20BF-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.