ZSE20B(F)-L is a digital vacuum sensor with IO-Link communication protocol support. When paired with an IO-Link master, measured values, and settings can be accessed from the HMI screen of a PLC. ZSE20B(F)-L incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit and 13 bits for the measured value. The 3-screen, 3-color display
Note Bracket A ZS-46-A1 Tapping screw: Nominal size 3 x 8 L (2 pcs.) Bracket B ZS-46-A2 Tapping screw: Nominal size 3 x 8 L (2 pcs.)
7 Specifications p. 8 Set Pressure Range and Rated Pressure Range p. 13 Functions p. 13 Internal Circuits and Wiring Examples p. 13 Dimensions p. 15 How to Order p. 9 Specifications p. 10 Set Pressure Range and Rated Pressure Range p. 13 Functions p. 13 Internal Circuits and Wiring Examples p. 14 Dimensions p. 15 5 High-Precision Digital Pressure Switch ZSE20m(F)/ISE20m Series 3-Screen Display
IODD file 1 1 ISE20B-L(-M)SMC-ISE20B-L-ymmdd-IODD1.1 2 ISE20B-L-PSMC-ISE20B-L-P-ymmdd-IODD1.1 3 ZSE20B-L(-M)SMC-ZSE20B-L-ymmdd-IODD1.1 4 ZSE20B-L-PSMC-ZSE20B-L-P-ymmdd-IODD1.1 5 ZSE20BF-L(-M)SMC-ZSE20BF-L-ymmdd-IODD1.1 6 ZSE20BF-L-PSMC-ZSE20BF-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)],
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation Manual
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, 73 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 75 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH W/ IO-LINK, VACUUM SWITCH, ZSE30, ZSE30A, 75 lb