SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20AF-T-P-N01-JK"
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, VACUUM SWITCH, ZSE30, ZSE30A, 73 lb

The ZSE20A(F) series is a high-precision digital pressure switch offering many popular ZSE features, with a streamlined selection of piping choices.  Compared to the ZSE20, the ZSE20AF adds a 2nd switch output, as well as an analog output, either voltage or current.  ZSE20A is vacuum rated, while the ZSE20AF is rated for vacuum and a low positive pressure range.  Each model in the ZSE20 family

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

output P PNP open collector 1 output Symbol Description Nil Units selection function1 M SI unit only2 P Units selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the units selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description

11 Specifications p. 12 Set Pressure Range and Rated Pressure Range p. 13 Functions p. 13 Internal Circuits and Wiring Examples p. 14 Dimensions p. 15 How to Order p. 19 Specifications p. 20 Set Pressure Range and Rated Pressure Range p. 21 Functions p. 21 Internal Circuits and Wiring Examples p. 22 Dimensions p. 23 Function Details p. 29 Made to Order Specifications p. 33 Safety Instructions

Display/Set pressure range 10.0 to -105.0 kPa -105.0 to 105.0 kPa -0.105 to 1.050 MPa Display/Min. setting unit 0.1 kPa 0.001 MPa Proof pressure 500 kPa 1.5 MPa Power supply Power supply voltage 12 to 24 VDC10%, ripple max. 10% (p-p) spec.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)