SMC Corporation of America
Elite Part Number Search
Search Results "ZSE10-N01-B-M"
10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

ZSE10(F) is a compact vacuum sensor suitable for mounting in panels or tight spaces.  This sensor has an integrated alphanumeric LED display with red and green LED switch indicators.  Switch delay time is 2.5ms, while current consumtion is 40mA.  Two sensing ranges are available, including low vacuum and compound pressure, consisting of low vacuum and pressure.  An auto-preset function helps

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Digital Pressure Switch Series ZSE10(F)/ISE10 How to Order Rated pressure range ISE10 0.100 to 1.000 MPa ISE10 For positive pressure M5 A M For vacuum/ compound pressure ZSE10 M5 B M Option 3 Rated pressure range Symbol Calibration certificate Nil K p ZSE10 ZSE10F 0.0 to 101.0 kPa 100.0 to 100 kPa Piping specifications Option 2 M5 female thread/Side ported Piping port None Nil M5 Panel mount

NPN or PNP open collector 2 outputs NPN or PNP open collector 1 output + Analog output (voltage) Output (Power consumption reduced by max 20%) Features 1 Digital Pressure Switch Series ZSE10(F)/ISE10 How to Order Rated pressure range ISE10 0.100 to 1.000 MPa ISE10 For positive pressure M5 A M For vacuum/ compound pressure ZSE10 M5 B M Option 3 Rated pressure range ZSE10 ZSE10F 0.0 to 101.0

Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2" and "H_2".

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: No Lead Wire, Adapter: None, Calibration Certificate: K (w/Certificate)

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: No Lead Wire, Adapter: None, Calibration Certificate: w/Certificate

Analog Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Mounting Hole: Presence, Display: Digital, Drive Component: Digital, Lamp: Presence, Acquired Standards: CE, Protection Structure: IP40, Application: For vacuum pressure [0 to -101 kPa], Unit Specifications: SI unit fixed, Lead Wire: Lead wire with connector (lead wire length: 2 m)

10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

10 to 60C (No freezing or condensation)Operating and stored: 35 to 85% RH (No condensation)1000 VAC for 1 min. between live parts and enclosure50 M or more between live parts and enclosure (at 500 VDC Mega)10 to 150 Hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in X, Y, Z directions for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa)

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: -, Adapter: -, Calibration Certificate: -