SMC Corporation of America
Elite Part Number Search
Search Results "VXR2260-10N-3C"
Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., VALVE,MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 3.96000 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (Holding

Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. VXR2 prevents damage of piping, equipment and generation of vibration through an integrated check valve and low valve closing speed. Variations include energized open (N.C) and energized closed (N.O) valves, bronze body material and NBR, FKM seal materials. Flow rate ranges from Cv of 6.5 to

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

IN Model/Valve Specifications Connection Max. operating pressure differential (MPa) Flow characteristics Water, Oil Weight (g) Min.operating pressure differential (MPa) Orifice size (mm) Max. system pressure (MPa) Model Thread Water Oil Cv converted Av x 10 -6 (m 2) 1 2 3 4 VXR2150-04 VXR2150-06 VXR2260-10 VXR2270-12 VXR2380-14 VXR2390-20 20 20 25 35 40 50 1250 160 180 290 530 720 1200 6.5

Water hammer relief, pilot operated 2 port solenoid valve series VXR is for use with water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 3.96000 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption W (Holding

Unit Remark Reference unit/s (default) 10n [reference unit/s] can be set. Reference unit/min 10n [reference unit/min] can be set. "%" of rated speed 10n [%] can be set. min1 (rpm) 10n [min1] can be set. Max. motor speed/40 (Hex.) Set "0" for common parameter 42. (2) Position The following units can be selected. Settings are made with common parameters 43 and 44.

x 14 7 Manual override VZ 7 14 P E P E 37.4 16 VS 29 32 43.8 VFN 4-PT 1/8 P , E port 2-3.5 Mounting hole 300 300 15.5 P = 10 1 2 3 4 5 n U side D side 40.2 15.5 46.2 19.4 A A 9.5 16.7 P = 10 n-M5 x 0.8 A port Dimensions Formula: L1 = 10n + 21, L2 = 10n + 7, n: Station (Max. 20 stations) n L L1 L2 2 41 27 3 51 37 4 61 47 5 71 57 6 81 67 7 91 77 8 9 10 121 107 11 131 117 12 141 127 13 151